CNC Setup Utility Manual
P/N 70000490C - Machine Constants
2-20
All rights reserved. Subject to change without notice.
10-December-04
Table 2-2, Machine Constants Setup
(Continued)
Machine Constant
Parameter
Function Settings
MC_2050:
X Display Resolution
.5 Micron
1
Micron
[Default]
2 Micron
5 Micron
10 Micron
MC_2051:
X In-position
Tolerance Range
range.
Range (0.0000–9.0000)
0.0004 (inch) [Default]
MC_2052:
X Default Feed Rate
Setting the X-axis Default Feed Rate
establishes a default feedrate for the X-
axis, wherever a feedrate has not been
programmed. This applies to
programmed blocks or MDI commands.
Jog moves in feed (that is, from a
manual panel) can have a different
feedrate.
Range (1.–50800.)
10. (inch/min) [Default]
MC_2053:
X Default Rapid Rate
Range (1.–50800.)
500. (inch/min) [Default]
Y-axis Setup Parameters
MC_2100:
Y Motor Encoder
Connector
The connection to which the motor
encoder for the Y-axis is connected.
X15
X16
[Default]
X17
X18
X19
MC_2101:
Y PWM Output
Connector
Defines the Y-axis PWM output
connector.
X55
X51
X52
[Default]
X53
X54
MC_2102:
Y Inverter Type
The inverter type identifies the Y-axis
inverter being used. Inputting the wrong
inverter type can result in undesired
axis behavior or inverter damage.
COMPACT
[Default]
PM 107
PM 115A
PM 123A
PM 132A
PM 148A
PM 207
PM 215A
PM 223A
(Continued…)