CNC Setup Utility Manual
P/N 70000490C - Machine Constants
2-32
All rights reserved. Subject to change without notice.
10-December-04
Table 2-2, Machine Constants Setup
(Continued)
Machine Constant
Parameter
Function Settings
U-axis Setup Parameters
MC_2300:
U Motor Encoder
Connector
The connection to which the motor
encoder for the U-axis is connected.
X15
X16
X17
X18
[Default]
X19
MC_2301:
U PWM Output
Connector
Defines the U-axis PWM output
connection.
X55
X51
X52
X53
X54
[Default]
MC_2302:
U Inverter Type
The inverter type identifies the U-axis
inverter being used. Inputting the wrong
inverter type can result in undesired
axis behavior or inverter damage.
COMPACT
[Default]
PM 107
PM 115A
PM 123A
PM 132A
PM 148A
PM 207
PM 215A
PM 223A
MC_2303:
U Motor Type
The U-axis motor type is identified by
the motor name. Inputting the wrong
motor number can result in undesired
axis behavior or motor damage.
NONE
[Default]
(See MC_2003 for a complete
setting list)
MC_2304:
U Linear Encoder
Connector
Selects the measuring system input for
the U-axis linear encoder.
NONE
[Default]
X1
X2
X3
X4
X6
(Continued…)