CNC Setup Utility Manual
P/N 70000490C - Machine Constants
All rights reserved. Subject to change without notice.
10-December-04
2-37
Table 2-2, Machine Constants Setup
(Continued)
Machine Constant
Parameter
Function Settings
MC_2352:
U Default Feed Rate
Setting the U-axis Default Feed Rate
establishes a default feedrate for the U-
axis, wherever a feedrate has not been
programmed. This applies to
programmed blocks or MDI commands.
Jog moves in feed (that is, from a
manual panel) can have a different
feedrate.
Range (1.–50800.)
10. (inch/min) [Default]
MC_2353:
U Default Rapid Rate
Range (1.–50800.)
500. (inch/min) [Default]
MC_2354:
U Axis Type
Defines the type of U-axis
Linear
[Default]
Rotary
MC_2355:
U Reset Rotary at 360
When U-axis is rotary, the position
display can be automatically reset to 0
(zero) when the axis reaches 360
degrees.
Yes
[Default]
No
MC_2356:
Synchronized to XYZ
Synchronizes U-axis to XYZ.
Yes
[Default]
No
MC_2357:
U M11/M10 Clamp
Enable
Enables clamping on U-axis using
M-codes M11/M10.
No
[Default]
Yes
Spindle-axis Setup Parameters
MC_2900:
Spindle Motor
Encoder Connector
The connection to which the motor
encoder for the spindle-axis is
connected.
X15
X16
X17
X18
X19
[Default]
MC_2901:
Spindle PWM Output
Connector
Defines the spindle-axis PWM output
connection.
X55
[Default]
X51
X52
X53
X54
MC_2902:
Spindle Inverter Type
The inverter type identifies the spindle-
axis inverter being used. Inputting the
wrong inverter type can result in
undesired spindle behavior or inverter
damage.
COMPACT
[Default]
PM 107
PM 115A
PM 123A
PM 132A
PM 148A
PM 207
PM 215A
PM 223A
(Continued…)