A-12
IZMSG Compact Electromagnetic Flowmeter
AIC 2071
F
Hardware Test Sequence
The hardware test sequence is used to test both the inputs and outputs of the
IZMSG flowmeter and the connected peripheral devices.
Press the keys
Õ
Ð
Ö
to activate the hardware test sequence.
WARNING!
Make certain the process that the flowmeter
is controlling is closed off or disconnected
before activating the hardware test sequence.
X = LED On
O = LED Off
LED Indicator
2 line of the display
Function
nd
D11 D14 D17 D20 D5 D6 D7 D8
all outputs off
the digital outputs are switched off
o
o
o
o
OUT1 On
only output
IMP1
is active - on
x
o
o
o
OUT2 On
only output
IMP2
is active - on
o
x
o
o
OUT3 On
only output
IMP3
is active - on
o
o
x
o
OUT4 On
only output
OUT4
is active - on
o
o
o
x
Anaout 4 mA
Anaout 20 mA
4 mA are at terminal
X8
#5/#6
20 mA are at terminal
X8
#5/#6
IN1=0 IN2=0 IN3=0 IN4=0
no input is activated
o
o
o
o
o
o
o
o
IN1=1 IN2=0 IN3=0 IN4=0
only input
IN1
is activated
x
o
o
o
o
o
o
o
IN1=0 IN2=1 IN3=0 IN4=0
only input
IN2
is activated
o
x
o
o
o
o
o
o
IN1=0 IN2=0 IN3=1 IN4=0
only input
IN3
is activated
o
o
x
o
o
o
o
o
IN1=0 IN2=0 IN3=0 IN4=1
only input
IN4
is activated
o
o
o
x
o
o
o
o
Содержание IZMSG
Страница 24: ...3 8 IZMSG Compact Electromagnetic Flowmeter AIC2071 Figure 3 8 Meter Body Converter Connections...
Страница 60: ...A 2 IZMSG Compact Electromagnetic Flowmeter AIC 2071 Converter...
Страница 61: ...Anderson Instrument Company A 3 AIC 2071...
Страница 62: ...A 4 IZMSG Compact Electromagnetic Flowmeter AIC 2071 Meter Body...
Страница 63: ...Anderson Instrument Company A 5 AIC 2071...
Страница 79: ......