![Anderson IZMSG Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/anderson/izmsg/izmsg_instruction-manual_2941751028.webp)
3-12
IZMSG Compact Electromagnetic Flowmeter
AIC2071
Figure 3-9. Converter 300-SJB2 Junction Board
Signal Output Connections
All connections to external devices are made from terminal blocks in the
converter on the 300-SJB2 Junction Board (see Figure 3-9 and table).
300 SJB2 Board
Function
D5, D6, D7, D8
LED indicators for digital outputs
D11, D14, D17, D20
LED indicators for digital inputs
S5
ABORT pushbutton (reset)
S4
ZERO-ADJUST pushbutton
X7
digital output terminals 21-28
digital input terminals 31-34 and 41-43
X8
analog output terminals 5 and 6; 4-20 mA
X9, X10
485 serial interface
X11
plug for battery (option)
TA, TxD, RxD
LED indicators for 485 serial interface