Anderson Instrument Company
4-3
AIC2071
LED Indicators
There are four LED indicators located inside the converter in the upper right
hand corner of the 300-SJB2 Junction Board (see Figure 3-9 in Section 3).
The indicators are numbered D5, D6, D7, and D8. They serve as status
indicators for digital outputs on terminal block X7. These visual status
indicators are helpful during start up for diagnosing and resolving problems
(see the following table).
LED
No.
Digital
Output
Term inal
State
Indicating
Notes
D5
26 and 25
Off
Flashing
On
Indicates pause between
pulses.
Pulse output at IMP1.
Pulse output at high
frequency at IMP1.
During low flowrate
conditions, the LED
may flash so
infrequently or briefly
that the flash will not be
visible.
During high flowrate
conditions, the LED
may flash so rapidly
that the LED appears to
be continuously on.
D6
24 and 23
Off
Flashing
On
Indicates pause between
pulses.
Pulse output at IMP2.
Pulse output at high
frequency at IMP2.
D7
22 and 21
Off
Flashing at
random
frequency
On
Reverse flow.
No flow (after successful
hydraulic zero procedure).
Forward flow in direction of
arrow.
Flow tube must be full
of product.
D8
28 and 27
Off
Flashing every
half second
Flashing every
second
On
No error condition exists.
Unsuccessful hydraulic zero
adjustment.
No current in coil drive circuit
to meter body.
Error condition exists.
On converters without
LCD display, an error
condition automatically
resets after 20 seconds
as long as the error
condition no longer
exists.
Содержание IZMSG
Страница 24: ...3 8 IZMSG Compact Electromagnetic Flowmeter AIC2071 Figure 3 8 Meter Body Converter Connections...
Страница 60: ...A 2 IZMSG Compact Electromagnetic Flowmeter AIC 2071 Converter...
Страница 61: ...Anderson Instrument Company A 3 AIC 2071...
Страница 62: ...A 4 IZMSG Compact Electromagnetic Flowmeter AIC 2071 Meter Body...
Страница 63: ...Anderson Instrument Company A 5 AIC 2071...
Страница 79: ......