Configuring Communication
51
10" Modero Touch Panels
Configuring and Using USB with a Virtual Master
NetLinx Studio can be setup to run a Virtual Master where the PC acts as the Master by supplying its own IP
Address for communication to the panel. The PC is first equipped with the USB driver, the panel is then
configured for USB communication, and then Studio is configured to act as the Master.
For a personal computer to establish a connection to a Modero panel via USB, the target computer must have
the appropriate AMX USB driver installed. This installation is bundled into the latest TPDesign4 software
setup process or can be downloaded independently from the main Application Files page on
www.amx.com
.
Step 1: Setup the Panel and PC for USB Communication
1.
If you do not currently have the latest version of TPDesign4, navigate to
www.amx.com
>
Tech Center
>
Downloadable Files
>
Application Files
>
NetLinx Design Tools
section of the website and locate the
AMX USB Driver executable (
AMX USBLAN Setup exe
).
2.
Download this executable file to a known location on your computer.
3.
Launch the Setup.exe and follow the on-screen prompts to complete the installation.
Step 2: Confirm the Installation of the USB Driver on the PC
The first time each AMX touch panel is connected to the PC it is detected as a new hardware device and the
USBLAN driver becomes associated with it (
panel specific
). Each time thereafter the panel is "recognized" as
a unique USBLAN device and the association to the driver is done in the background. When the panel is
detected for the
first time
some user intervention is required during the association between panel and driver.
1.
After the installation of the USB driver has been completed, confirm the proper installation of the large
Type-A USB connector to the PC's USB port, and restart your machine.
2.
Connect the terminal end of the 12 VDC-compliant power supply cable to the power connector on the
rear/side of the touch panel and then apply power.
3.
After the panel powers-up, press and hold the grey Front Setup Access button (
for 3 seconds
) to continue
with the setup process and proceed to the Setup page.
4.
Select
Protected Setup
>
System Settings
(located on the lower-left) to open the System Settings page
(FIG. 54).
The mini-USB connector
MUST
be plugged into an already active panel before the
PC can recognize the connection and assign an appropriate USB driver. This driver is
part of both the NetLinx Studio and TPDesign4 software application installations.
If the panel is already powered, continue with steps 3.
The panel MUST be powered and configured for USB communication before
connecting the mini-USB connector to the panel’s Program Port.
FIG. 54
USB System Settings page - using a USB Connection Type
No connection is established until
the Virtual Master becomes
active within Studio
Red
Connection Status icon -
Green
Connection Status icon -
indicates no connection to a Virtual
indicates communication to a Virtual
Master
Master
Yellow
Connection Status icon -
indicates an unreliable network
connection
Содержание modero NXD-CV10
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV10 10 Modero Touch Panel Last Revised 7 2 2012 ...
Страница 44: ...CV10 Touch Panel Accessories 32 10 Modero Touch Panels ...
Страница 58: ...Installation 46 10 Modero Touch Panels ...
Страница 88: ...Configuring Communication 76 10 Modero Touch Panels ...
Страница 98: ...Upgrading Modero Firmware 86 10 Modero Touch Panels ...
Страница 192: ...Appendix A 180 10 Modero Touch Panels ...
Страница 206: ...Troubleshooting 194 10 Modero Touch Panels ...
Страница 207: ...Appendix 195 10 Modero Touch Panels ...