Firmware Pages and Descriptions
88
10" Modero Touch Panels
Setup Page
This page (FIG. 86) centers around basic Modero panel properties such as: Connection Status of the panel,
Display Timeout, Inactivity Page Flip Time, Inactivity page file, and the Panel Brightness.
The elements of the Setup page are described in the table below:
Setup Navigation Button Elements (Cont.)
Video Adjustment:
Press the Video Adjustment button to access the Video Adjustment page where
you can set the video properties for incoming video.
• This button only appears on Color Video (CV) capable touch panels.
• Refer to the
Video Adjustment Page
section on page 95 for more detailed
information.
Battery Base:
Press the Battery Base button to access the Battery Base page where you can
modify and monitor NXT-BP Modero Power Pack parameters.
• This button only appears when a Modero Table Top panel (NXT) is connected
to an NXA-BASE/B battery base.
• Refer to the
Battery Base Page
section on page 96 for more detailed
information.
FIG. 86
Setup page
Setup Page Elements
Exit:
Returns you to the Main touch panel page. In this case, the previous page is the
default Main page.
Connection Status icon:
This visual display of the connection status allows the user to have a current
update of the panel’s connection status regardless of what page is currently
active.
• A Lock only appears on the icon if the panel has established a connection
with a currently secured target Master (
requiring a username and password
).
Connection Status:
Displays whether the panel is communicating externally, the encryption status
of the communicating Master, what connection type is being used (
Ethernet or
USB
), and what System the panel is a part of.
This visual display of the connection status is also reflected at the upper-right of
each firmware page. This allows the user to have a current visual update of the
panel’s connection status regardless of what page is currently active.
• When a connection is established, the message displayed is either:
"
Connected via Ethernet
" or "
Connected via USB
".
• If no connection can be established by the Modero panel, it will continue to try
and establish a connection while displaying: "
Attempting via ...
".
• The word "
Encrypted
" appears only when an encrypted connection is
established with a target Master.
• The panel must be rebooted before incorporating any panel communication
changes and detecting any active Ethernet connections.
The Ethernet connection is not detected until after a reboot.
Battery Base button doesn’t appear
until NXT is connected to a BASE/1
Connection Status
Red
Connection Status icon -
Green
Connection Status icon -
indicates no connection
indicates communication
to a Master
to a Master
Содержание modero NXD-CV10
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV10 10 Modero Touch Panel Last Revised 7 2 2012 ...
Страница 44: ...CV10 Touch Panel Accessories 32 10 Modero Touch Panels ...
Страница 58: ...Installation 46 10 Modero Touch Panels ...
Страница 88: ...Configuring Communication 76 10 Modero Touch Panels ...
Страница 98: ...Upgrading Modero Firmware 86 10 Modero Touch Panels ...
Страница 192: ...Appendix A 180 10 Modero Touch Panels ...
Страница 206: ...Troubleshooting 194 10 Modero Touch Panels ...
Страница 207: ...Appendix 195 10 Modero Touch Panels ...