Firmware Pages and Descriptions
127
10" Modero Touch Panels
Certificate files frequently use 5 file extensions. It can be confusing because there is not a one to one
correspondence. The following table shows the possible file extension used for each certificate type:
It is important to note which certificate types are supported by the different certificate fields used on the
configuration screens (PEAP, TTLS, and TLS). The following table outlines the firmware fields and their
supported certificate types.
System Settings Page
The System Settings page (FIG. 114) sets the Secondary DNS Address information with its corresponding IP
communication parameters, NetLinx Master communication settings, and reads the device number assigned to
the Modero panel.
The elements of the System Settings page are described in the table below:
Certificates and their Extensions
Certificate Type
Possible File Extensions
PEM
.cer
.pem
.pvk
DER
.cer
.der
PKCS12
.pfx
Certificate Types Supported by the Modero Firmware
Configuration Field Name
Certificate File Type Supported
Certificate Authority
field
PEM and DER
Client Certificate
field
PEM and DER
Private Key
field
.PEM, DER, and PKCS12
FIG. 114
System Settings page showing default values (reads and assigns values to the panel and Master)
System Settings Page Elements
Back:
Saves the changes and returns you to the previously active touch panel page.
Connection
Status icon:
This visual display of the connection status allows the user to have a current visual
update of the panel’s connection status regardless of what page is currently active.
• A Lock only appears on the icon if the panel has established a connection with a
currently secured target Master (
requiring a username and password
).
IP Settings:
Sets the IP communication values for the panel and contains:
DHCP/Static
Sets the panel to either DHCP or Static communication modes.
•
DHCP (Dynamic Host Configuration Protocol)
assigns IP Addresses from client stations
logging onto a TCP/IP network via a DHCP server.
•
Static IP
is a permanent IP Address that is assigned to a node in a TCP/IP network.
IP Address
Sets the secondary IP Address assigned to the panel.
IP Settings section
Master Connection section
(NetLinx Master properties)
Master Connection features do not take
effect until the panel is rebooted
Red
fields are user-editable
Blue
fields cycle through choices
Grey
fields are read-only
Содержание modero NXD-CV10
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV10 10 Modero Touch Panel Last Revised 7 2 2012 ...
Страница 44: ...CV10 Touch Panel Accessories 32 10 Modero Touch Panels ...
Страница 58: ...Installation 46 10 Modero Touch Panels ...
Страница 88: ...Configuring Communication 76 10 Modero Touch Panels ...
Страница 98: ...Upgrading Modero Firmware 86 10 Modero Touch Panels ...
Страница 192: ...Appendix A 180 10 Modero Touch Panels ...
Страница 206: ...Troubleshooting 194 10 Modero Touch Panels ...
Страница 207: ...Appendix 195 10 Modero Touch Panels ...