Configuring Communication
68
12” and 15” Modero Touch Panels
3.
Press the
System Number
field to launch a Keypad and enter the value for the system number of the
NetLinx Master.
This value can be obtained from the NetLinx Studio program > OnLine Tree of the
Workspace window.
4.
Do not alter the IP Settings on the System Connection page, as this field is not applicable to this
connection mode.
5.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
6.
Press the on-screen
Reboot
button to both save any changes and restart the panel.
7.
Press the grey Front Setup Access button for
3 seconds
to open the Setup page and confirm there is an
active connection.
Using G4 Web Control
®
to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web. This
feature works in tandem with the new browser-capable NetLinx Security firmware update (
build 300 or
higher
). G4 Web Control is only available with the latest Modero panel firmware.
Refer to the
G4 Web Control Page
section on page 94 for more detailed field information.
1.
Press the grey Front Setup Access button for
3 seconds
to open the Setup page.
2.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the Protected Setup
page and display an on-screen keypad.
3.
Enter
1988
into the Keypad’s password field (
1988 is the default password
).
4.
Press
Done
when finished.
5.
Press the
G4 Web Control
button to open the G4 Web Control page (FIG. 66).
6.
Press the
Enable/Enabled
button until it toggles to
Enabled
(
light blue color
).
The NetLinx Master and the Modero panel must both be on the same Subnet.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from
www.amx.com
. Refer to your NetLinx Master Instruction
Manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
FIG. 66
G4 Web Control page