Firmware Pages and Descriptions
99
12” and 15” Modero Touch Panels
Calibration Page
This page (FIG. 93) allows you to calibrate the input touch device (touch panel) using the pre-selected touch
driver.
Press and hold the grey Front Setup Access button (below the Modero LCD) for 6 seconds to access
the Calibration page.
Press the crosshairs to calibrate the panel and return to the last active firmware page.
Secondary Connection Page
The Secondary Connection page (FIG. 94) sets the communication information for the installed wireless
interface card. This information includes its corresponding IP communication parameters, wireless
communication settings, and read the device number assigned to the Modero panel. These panels can use the
optional NXA-WC80211b AMX Wireless Interface Card for wireless communication. This card also supports
Wired Encryption Protocol
(WEP) encryption of 64-bit and 128-bit key lengths. Refer to both the
Secondary
Connection Page - Wireless Access Overview
section on page 56 and
Configuring a Wireless Access
Connection
section on page 57 for more detailed information of setting up the Modero panel for wireless
network access.
The elements of the Secondary Connection page are described in the table below:
FIG. 93
Calibration page (actually 3 separate screens)
The request to touch the crosshairs
is the first on-screen message
Calibration successful
is the second
on-screen message that appears
On-screen crosshairs used for
calibration of the touch device
after the calibration process is
completed
If the calibration was improperly set and you cannot return to the Calibration
page (through the panel’s firmware);
you can access this firmware page via
G4 WebControl where you can navigate to the Protected Setup page and press the
Calibrate button through your VNC window.
This action causes the panel to go to the Calibration page seen above, where you
can physically recalibrate the actual touch panel again using the above procedures.
FIG. 94
Secondary Connection page (showing default values)
IP Settings section
Wireless Settings section
Red
fields are user-editable
Blue
fields cycle through choices
Grey
fields are read-only
Содержание Modero NXD-CA12
Страница 20: ...Introduction 10 12 and 15 Modero Touch Panels...
Страница 60: ...Installation Procedures 12 and 15 Panels 50 12 and 15 Modero Touch Panels...
Страница 82: ...Configuring Communication 72 12 and 15 Modero Touch Panels...
Страница 90: ...Upgrading Modero Firmware 80 12 and 15 Modero Touch Panels...