AMX Modero NXD-CA12 Скачать руководство пользователя страница 1

O p e r a t i o n / R e f e r e n c e   G u i d e

T o u c h   P a n e l s

12" & 15” Modero

®

 Touch Panels

NXD/T-CA12, NXD/T-CV12
NXD/T-CA15, NXD/T-CV15

L a s t   R e v i s e d :   8 / 0 3 / 2 0 1 0

Содержание Modero NXD-CA12

Страница 1: ...Operation Reference Guide Touch Panels 12 15 Modero Touch Panels NXD T CA12 NXD T CV12 NXD T CA15 NXD T CV15 Last Revised 8 03 2010...

Страница 2: ...ked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled w...

Страница 3: ...g CAT5 Suppression Ferrites 18 NXA WC80211b Wireless Interface Card FG2255 02 19 Product Specifications 19 Installing the wireless card 20 NXA CFTP an NXA EXM Modules 20 Installation of the Compact Fl...

Страница 4: ...dures 12 and 15 Panels 33 Overview 33 Unpacking the Panel 33 Installing the Internal Components 33 Upgrading to the MB TP12 MB TP15 VESA Mounting Kit 33 Removing the Original Modero Back Box 33 Instal...

Страница 5: ...IP Settings 62 IP Settings section Configuring a DHCP Address over Ethernet 62 IP Settings section Configuring a Static IP Address over Ethernet 63 Step 2 Choosing a Master Connection Mode Setting 63...

Страница 6: ...age 89 Battery Base Page 89 Protected Setup Navigation Buttons 91 Protected Setup Page 92 G4 Web Control Page 94 Sensor Setup Page 95 Using the Automated Brightness Control feature DIM Mode 97 Passwor...

Страница 7: ...and ID numbers 112 Border styles 113 Button Commands 114 ANI 114 APF 115 BAT 115 BAU 115 BCB 116 BCF 116 BCT 116 BDO 117 BFB 117 BIM 117 BLN 117 BMC 118 BMF 119 BMI 120 BML 120 BMP 121 BNC 121 BNN 121...

Страница 8: ...EF 129 TXT 129 Text Effect Names 130 UNI 130 Button Query Commands 131 BCB 132 BCF 132 BCT 133 BMP 133 BOP 134 BRD 134 BWW 135 FON 135 ICO 136 JSB 136 JSI 137 JST 137 TEC 138 TEF 138 Panel Runtime Ope...

Страница 9: ...S 143 VKS 143 VKB 143 WAKE 143 Embedded Codes 144 Panel Setup Commands 145 MUT 145 PWD 145 PWD 145 RPP 145 VOL 145 Dynamic Image Commands 146 BBR 146 RAF 146 RFR 146 RAF RMF Embedded Codes 147 RMF 147...

Страница 10: ...Formatting Codes for Bargraphs Joysticks 153 Text Area Input Masking 154 Input mask character types 154 Input mask ranges 155 Input mask next field characters 155 Input mask operations 155 Input mask...

Страница 11: ...els to communicate with a NetLinx Master via a standard 802 11b Wireless Access Point and an NXA BASE B battery base kit that allows the NXT to function off the charge from two included NXT BP batteri...

Страница 12: ...12 VDC stand alone Startup current draw 3 0 A 12 VDC stand alone Power Requirements CA15 Constant current draw 3 45 A 12 VDC stand alone Startup current draw 5 1 A 12 VDC stand alone Minimum power sup...

Страница 13: ...play Note The light sensor can be adjusted via the Sensor Setup page page 95 Motion sensor PIR Proximity Infrared Detector to wake the panel when the panel is approached Activation range 20 vertically...

Страница 14: ...e Top Cable CA2250 50 provided with all NXT Table Top panels Optional Accessories CB TP12 FG031 10 12 metallic conduit box for Wall Mount installations CB TP15 FG032 10 15 metallic conduit box for Wal...

Страница 15: ...TPD4 files The new G4 graphics technology is supported by the release of the latest TPDesign4 Touch Panel Design Program version 2 5 or higher Specifications for Color Active Touch Panels Cont Option...

Страница 16: ...x 11 52 x 11 60 x 3 50 29 27 cm x 29 47 cm x 8 89 cm MB TP12 VESA mounting box 12 37 x 12 58 x 3 52 31 42 cm x 31 95 cm x 8 94 cm Dimensions 15 HWD NXD CV15 with faceplate 14 37 x 15 20 x 3 31 36 50 c...

Страница 17: ...Button Assignments Button assignments can only be adjusted in TPD4 and not on the panels Button channel range 1 4000 button push and Feedback per address port Button variable text range 1 4000 per ad...

Страница 18: ...mperature 10 C 50 F to 40 C 104 F Operating Humidity 20 to 85 RH Storage Temperature 20 C 4 F to 60 C 140 F Storage Humidity 5 to 85 RH Included Accessories Installation Kit for 12 15 NXT panels KA225...

Страница 19: ...ttery charger for NXT BP batteries Charges batteries in 8 hours PSN4 4 Power Supply FG423 45 PSN6 5 Power Supply FG423 41 Upgrade Extended Memory NXA EXM128M 128 MB memory card FG079 01 NXA EXM256M 25...

Страница 20: ...Introduction 10 12 and 15 Modero Touch Panels...

Страница 21: ...FG2250 11K 12 Color Video Table Top touch panel with Video inputs includes an NXA AVB Audio Video Breakout Box NXD CV12 Kit FG2251 12K 12 Color Video Wall Mount touch panel with video inputs includes...

Страница 22: ...es the differential audio and video signals to from the touch panel panel type dependant Rear Components 6 pin 3 5 mm Phoenix connector for in bound left right channel audio 4 pin 3 5 mm Phoenix conne...

Страница 23: ...anel FIG 8 NXA AVB Breakout Box connector wiring diagram AUDIO IN 6 pin mini Phoenix connector divided into left and right audio channels Each channel is divided into GND IN and IN terminal cable conn...

Страница 24: ...opposite negative voltage The advantage of balanced audio over unbalanced audio is its ability to reject external interference added as the signal is carried over the wire The receiving equipment tak...

Страница 25: ...nector to route power from the external breakout box to the target panel Included Accessories One Modero Table Top Cable CA2250 70 Other AMX Equipment Note All touch panels routing an Audio Video sign...

Страница 26: ...p Cable Specifications Cont Other AMX Equipment Cont Installation Kit for 15 and 17 NXT panels KA2251 04 2 pin mini Phoenix connector 41 5025 Three Phillips head screws 4 20 x 0 250 Black 80 0114 08 O...

Страница 27: ...HITE ORANGE ORANGE P3 WHITE GREEN GREEN PAIR TWISTED AT VARIED LAYS TO MINIMIZE CROSS TALK ELEMENT 2 CONDUCTOR INSULATION COLOR CODE CABLE BINDER FINAL ASSEMBLY AXIS TO MINIMIZE DIAMETER BINDER JACKET...

Страница 28: ...Audio Video cable into the groove along the inside of the enclosure 4 Snap the enclosure shut with the cable inside and you re done 5 Repeat this process again only when installing an additional CAT5...

Страница 29: ...certified and available for use in North America ONLY NXA WC80211b Specifications Dimensions HWD 0 197 x 2 13 x 3 39 5 0 mm x 54 0 mm x 86 0 mm Description 2 4 GHz Direct Sequence Spread Spectrum DSS...

Страница 30: ...ion to a target WAP such as the NXA WAP200G NXA CFTP an NXA EXM Modules Every Modero panel is shipped with two factory default modules an EXM Memory Module and a Compact Flash card Each module has 64...

Страница 31: ...uter housing and rest the base on a flat surface 5 Tilt the LCD backward to a 45 angle 6 In a single motion carefully pull the outer housing up and then out away from the LCD panel to expose the inter...

Страница 32: ...ard connector pins 4 Slip your finger into the opening between the connector pins and the card and push the card out to remove it 5 Remove the upgrade card from its anti static bag 6 Insert the upgrad...

Страница 33: ...otate the entire unit back onto a flat surface then insert all connectors and apply power Installation of the Compact Flash Card WallMount Panel These procedures involves removing the outer housing in...

Страница 34: ...back box to the internal panel casing FIG 23 6 Lift the outer housing from the internal panel casing to access the internal circuit board FIG 23 FIG 22 Screw locations on the attached I O connector pl...

Страница 35: ...he Stereo Output jack as seen in FIG 22 Installation of the EXM memory module Table Top Panel These procedures involves removing the outer housing installing the new memory module and then securely re...

Страница 36: ...he NXD Outer Housing Complete the procedures outlined within the Step 3 Replacing the NXD Outer Housing section on page 25 NXT BP Power Pack FG2255 10 The NXT BP Power Pack FIG 25 is a rechargeable Li...

Страница 37: ...o Panel section on page 28 for more detailed installation and usage instructions Product Specifications FIG 26 NXA BASE B and NXT BP combo NXA BASE B Specifications Dimensions HWD 1 13 x 8 63 x 11 81...

Страница 38: ...male connector and base female connector FIG 28 4 Carefully place the Modero panel over the base alignment pegs FIG 28 and FIG 29 5 Gently apply downward pressure until the panel is securely mounted t...

Страница 39: ...y base open the battery compartment FIG 30 by pulling the handle outwards This compartment houses two NXT BP batteries 2 Install the NXT BP battery label side down 3 Align the battery connectors with...

Страница 40: ...n FIG 30 3 Insert a 2 pin connector from a power supply to the rear PWR connector on the NXT Modero panel The charge status bargraph indicators on the Battery Base page indicate when the batteries are...

Страница 41: ...unit by connecting the power cord with plug into a power outlet that meets the requirements outlined in the Specifications section for the NXT CHG FIG 31 NXT CHG Kit consists of one NXT CHG charger an...

Страница 42: ...D Indicator section on page 32 section for LED information Recalibrating the batteries The recalibration process increases the accuracy of the battery charge level Recalibration of the batteries is on...

Страница 43: ...both the 12 FG031 50 and 15 panel FG032 50 is identical and requires 3 main processes Removing the pre existing back box and installing the new VESA back box Threading cables through the strain relie...

Страница 44: ...ver the internal panel casing with the cable routing hole on the right side of the panel 3 Re install and secure the four pan head Housing Screws into their pre drilled holes along the edges of the MB...

Страница 45: ...relief grommet over the desired cable location 5 Firmly push the Strain Relief Grommet into the opening toward the inside until the rim is securely flush against the back of the rear plastic cover FIG...

Страница 46: ...step secures the NXD unit to the rim of the rear plastic cover 9 Align a VESA mount connector purchased separately to the four 8 32 screw holes on the back of the rear plastic cover FIG 34 10 Insert...

Страница 47: ...allic boxes that are secured onto stud beams prior to the installation of a solid surface Installation procedures and configurations can vary This section describes the installation procedures for the...

Страница 48: ...panel directly into a pre wall installed conduit box a solid surface or drywall and optional NXA RK Rack Mount Kit Installing the NXD panel within a Conduit Box The conduit box must be mounted prior t...

Страница 49: ...the four securing 4 40 Mounting Screws into their corresponding holes located along the sides of the NXD FIG 38 and FIG 39 8 Replace the magnet faceplate A in FIG 39 back onto the main NXD unit B in...

Страница 50: ...ywall before beginning 2 Cut out the surface for the 12 inch Wall Mount using the dimensions shown in FIG 40 and for the 15 inch Wall Mount using the dimensions shown in FIG 41 Be sure to cut out the...

Страница 51: ...nd applying power Verify the panel is receiving power and functioning properly to prevent repetition of the installation 7 Disconnect the terminal end of the power cable from the connected PSN power s...

Страница 52: ...faceplate 12 Connect the terminal RJ 45 Ethernet and any optional audio video wiring to their respective locations on either the NXA AVB Breakout Box Ethernet port or NetLinx Master 13 Reconnect the t...

Страница 53: ...ace for the 12 inch Wall Mount using the dimensions shown in FIG 43 and for the 15 inch Wall Mount using the dimensions shown in FIG 44 Mounting screws are secured through holes located at the left an...

Страница 54: ...cted to power supply before plugging in the 2 pin power connector 6 Test the incoming wiring by connecting the panel connections to their terminal locations and applying power Verify the panel is rece...

Страница 55: ...on on page 47 for pinout descriptions Leave enough slack to accommodate any re positioning of the panel 3 Connect all data and power wiring connectors to their corresponding locations along the side o...

Страница 56: ...ounded Phillips head screwdriver to secure the NXA RK with connected NXD unit to the equipment rack using 10 32 screws not included 10 Place the magnet faceplate back onto the main NXD unit by grippin...

Страница 57: ...in 3 5 mm mini Phoenix connector FIG 48 1 Insert the PWR and GND wires on the terminal end of the PSN 2 pin 3 5 mm mini Phoenix cable Match the wiring locations of the on both the power supply and the...

Страница 58: ...SNet Pinout Information EIA TIA 568 B Pin Wire Color Function Polarity 1 Orange White Transmit 2 Orange Transmit 3 Green White N A 4 Blue Ground 5 White Blue 12 VDC 6 Green N A 7 White Brown Receive 8...

Страница 59: ...rnet LEDs Ethernet RJ 45 Pinouts and Signals Pin Signals Connections Pairing Color 1 TX 1 1 1 2 Orange White 2 TX 2 2 Orange 3 RX 3 3 3 6 Green White 4 no connection 4 4 Blue 5 no connection 5 5 Blue...

Страница 60: ...Installation Procedures 12 and 15 Panels 50 12 and 15 Modero Touch Panels...

Страница 61: ...Calibrating the Modero Panel 1 Press and hold the grey Front Setup Access button FIG 51 for 6 seconds passing over the Setup page to access the Calibration setup page FIG 52 The panel should first be...

Страница 62: ...ress the Back button and recalibrate the panel using the above steps 4 Exit this Calibration Test page by pressing the Back button to return to the Protected Setup page FIG 52 Touch Panel Calibration...

Страница 63: ...000 6 Press Done to close the keypad assign the number and return to the Protected Setup page If you are currently using a Static IP Address continue with the IP Settings section Configuring a Static...

Страница 64: ...e panel page to open the Protected Setup page 11 Press the System Connection button located on the Protected Setup page to open the System Connection page FIG 56 and begin configuring the communicatio...

Страница 65: ...le to ICSNet Refer to the System Connection Page section on page 103 for more information about the fields on this page 7 Do not alter any of the grey fields in the IP Settings section These fields ar...

Страница 66: ...t match those of the pre installed wireless interface card installed within the panel Wireless Access Points are the cornerstone of any wireless network A Wireless Access Point acts as a bridge betwee...

Страница 67: ...rameters within the Secondary Connection page This page only configures the card to communicate to a target WAP such as the NXA WAP200G it is still necessary to tell the panel which Master it should b...

Страница 68: ...ess the Domain field to open a Keyboard enter the resolvable domain Address this is provided by your System Administrator and equates to a unique Internet name for the panel and press Done when comple...

Страница 69: ...il it reads Clear Text default 9 Verify the IP Settings section fields have been properly set Refer to the Step 1 Configuring the Panel s IP Settings section on page 57 for detailed information 10 Pre...

Страница 70: ...to join the network if the panel s SSID matches the WAP s SSID Shared Key Authentication requires that the panel and the Wireless Access Point have the same WEP Key to authenticate 8 Toggle the Encryp...

Страница 71: ...ood and Excellent Configuring multiple wireless Moderos to communicate with a target WAP 1 Follow the steps outlined above for the particular method of wireless access 2 Press the Generate button to l...

Страница 72: ...ion until the choice cycles to DHCP 4 Press the optional Host Name field to open a Keyboard and enter the Host Name information 5 Press Done after you are finished assigning the alpha numeric string o...

Страница 73: ...ystem Connection page URL is the most common method Master Connection MODE options Step 3 Configuring the Ethernet Connection Type Before beginning 1 Verify the panel has been configured to communicat...

Страница 74: ...left to open the System Connection page FIG 62 Master Connection Virtual Master communication over Ethernet Before beginning 1 Verify the panel has been configured to communicate either through an Eth...

Страница 75: ...ick Start Run to open the Run dialog Enter cmd into the Open field and click OK to open the command DOS prompt From the C command line enter ipconfig to display the IP Address of the PC This informati...

Страница 76: ...tem Connection Page section on page 103 for more information about the fields on this page 2 Press the Mode field until the choices cycle to the word URL By selecting URL the System Number field becom...

Страница 77: ...ss the Mode field to set the connection Mode until the choices cycle to the word Listen 4 Enter a username and password into their respective fields if the target Master has been previously secured 5...

Страница 78: ...0 or higher G4 Web Control is only available with the latest Modero panel firmware Refer to the G4 Web Control Page section on page 94 for more detailed field information 1 Press the grey Front Setup...

Страница 79: ...e Web Control name 11 Press the Web Control Password field to open the Web Password keyboard 12 From the Web Password keyboard enter a unique alpha numeric string to be assigned as the G4 Authenticati...

Страница 80: ...Both HTTP and HTTPS Ports are enabled by default via the Manage System Server page If the Master has been previously configured for secured communication click OK to accept the AMX SSL certificate if...

Страница 81: ...in the secondary browser window 10 Enter the Web Control session password into the Session Password field FIG 69 This password was previously entered into the Web Control Password field within the G4...

Страница 82: ...Configuring Communication 72 12 and 15 Modero Touch Panels...

Страница 83: ...net connection direct or wireless Step 1 Prepare the Master for communication via an IP 1 Obtain the IP Address of the NetLinx Master from your System Administrator if you do not have an IP Address fo...

Страница 84: ...P Address and alter their properties by clicking the Edit button and making your changes 10 Enter the IP Address into the TCP IP Address field This information is obtained from either your System Admi...

Страница 85: ...ick the associated System number from the Workspace window and select Refresh System to detect of all devices on the current system establish a new connection to the Master and refresh the System list...

Страница 86: ...are process has finished 11 Click Send to begin the transfer The file transfer progress is indicated on the bottom right of the dialog FIG 73 12 Click Close after the panel reboots to return to the ma...

Страница 87: ...to the battery base Once the batteries are installed close the compartment Reconnect all rear connectors to the NXT panel 1 Complete the instructions for configuring the NetLinx Master for IP communic...

Страница 88: ...Modero panel value is 10001 The NXA BASE B will not appear on the system listing 4 Locate the latest firmware file from the www amx com Tech Center Downloadable Files Firmware Files Modero Battery Bas...

Страница 89: ...resh of all project systems establishes a new connection to the Master and populates the System list with devices on your particular system 15 Press and hold the grey Front Setup Access button below t...

Страница 90: ...Upgrading Modero Firmware 80 12 and 15 Modero Touch Panels...

Страница 91: ...el Information button to access the Panel Information page and view panel specific information such as resolution memory etc read only Refer to the Panel Information Page section on page 85 for more d...

Страница 92: ...nitor NXT BP Modero Power Pack parameters This button only appears when a Modero Table Top panel NXT is connected to an NXA BASE B battery base Refer to the Battery Base Page section on page 89 for mo...

Страница 93: ...nel can remain idle before activating the sleep mode When the device goes into sleep mode the LCD is powered down Press the UP DN buttons to increase decrease the time until the panel times out Range...

Страница 94: ...s on the icon if the panel has established a connection with a currently secured target Master requiring a username and password File Name Displays the name of the TPDesign4 project file downloaded to...

Страница 95: ...e panel High Address Displays the high address address count value for the panel High Channel Displays the high channel channel count value for the panel High Level Displays the high level level count...

Страница 96: ...te Display fields Currently selected The only way to modify a panel s time without altering the Master is to use NetLinx Code Time Date Setup Page Elements Back Returns you to the previously active to...

Страница 97: ...the UP DN buttons to alter the minute value range 0 59 Select the Second field and use the UP DN buttons to alter the second value range 0 59 Modero touch panels do not have an on board clock This pa...

Страница 98: ...active button Internal Sound Level This section allows you to adjust the current sound level on the internal panel speaker Use the UP DN buttons to adjust the volume output on the internal speakers r...

Страница 99: ...tablished a connection with a currently secured target Master requiring a username and password Settings The Default Settings button sets the video settings to their default values indicated in this t...

Страница 100: ...ilable on the battery for use before the panel displays a very low battery warning This indicates a near term panel shutdown Range 3 15 default 5 min This value can never exceed the Low Battery Warnin...

Страница 101: ...term quality in the context of a battery refers to the current capacity relative to the batteries rated capacity For example after constant use a battery may be operating at 75 of its rated capacity...

Страница 102: ...ion parameters used by the NXA WC80211b interface card located within the rear side of a Modero panel Refer to the Secondary Connection Page section on page 99 for more detailed information System Con...

Страница 103: ...ation page Reboot Panel Pressing this button causes the panel to restart after saving any changes System Recovery Allows you to either reset the touch panel to factory default settings and or wipe out...

Страница 104: ...urrently active A Lock only appears on the icon if the panel has established a connection with a currently secured target Master requiring a username and password G4 Web Control Settings Sets the IP c...

Страница 105: ...Allows you to enter the G4 Authentication session password associated for VNC web access of this panel Web Control Port Allows you to enter the port value that the VNC Web Server runs on Default value...

Страница 106: ...evel bargraph displays a horizontal bargraph indicating the current value of the light level detected by the on board photo sensor This bargraph provides a visual representation of the numeric value d...

Страница 107: ...lements Cont Dim Mode Minimum Brightness Allows you to alter the sensitivity of the Modero panel light sensor Toggle the Enable Enabled button to either active inactive the DIM Mode feature Enable act...

Страница 108: ...hting of the room is at 40 FIG 92 Password Setup page Password Setup Page Elements Back Saves the changes and returns you to the previously active touch panel page Connection Status icon This visual d...

Страница 109: ...section on page 56 and Configuring a Wireless Access Connection section on page 57 for more detailed information of setting up the Modero panel for wireless network access The elements of the Secondar...

Страница 110: ...e primary DNS server being used by the Modero panel for host name lookups DNS Domain Name System is software that lets users locate computers on a local network or the Internet TCP IP network by host...

Страница 111: ...generate all four WEP keys which are compatible only among Modero panels Note The code key generator on Modero panels use the same key generation formula Therefore this same Passphrase generates ident...

Страница 112: ...uality of the link as descriptive colored text from the wireless NIC to the Wireless Access Point in real time The bargraph has been replaced with a descriptions None Poor Fair Good Very Good and Exce...

Страница 113: ...l to either DHCP or Static communication modes DHCP Dynamic Host Configuration Protocol assigns IP Addresses from client stations logging onto a TCP IP network via a DHCP server Static IP is a permane...

Страница 114: ...ed on Modero panels which are not equipped with a rear USB port Mode Cycles between the different connection modes URL Listen and Auto ETHERNET Only URL In this mode enter the IP URL Master Port Numbe...

Страница 115: ...ates for General buttons 1 Off state and 2 On state Level Range 1 600 Default level value 0 255 can be set up to 1 65535 Address port Range 1 100 These button assignments can only be adjusted in TPD4...

Страница 116: ...the named hide effect Syntax PHE popup page name hide effect name Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On hide effect name Refers to the popup effect...

Страница 117: ...popup page Popup1 on the current page PPG Toggle a specific popup page on either a specified page or the current page If the page name is empty the current page is used see example 2 Toggling refers t...

Страница 118: ...mple 2 If the popup page is already on do not re draw it This command works in the same way as the Show Popup command in TPDesign4 Syntax PPN popup page name page name Variable popup page name 1 50 AS...

Страница 119: ...ffect time Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On show effect time Given in 1 10ths of a second Example SEND_COMMAND Panel PST Popup1 50 Sets the Pop...

Страница 120: ...another On Off Example 2 SEND_COMMAND Panel PPOG Popup1 Toggles the popup page Popup1 on the current page from one state to another On Off PPON Activate a specific popup page to launch on either a spe...

Страница 121: ...223 223 38 Cyan 0 191 191 39 Medium Cyan 0 159 159 40 Dark Cyan 0 127 127 41 Very Dark Cyan 0 95 95 42 Very Light Aqua 0 128 255 43 Light Aqua 0 112 223 44 Aqua 0 96 191 45 Medium Aqua 0 80 159 46 Da...

Страница 122: ...82 Grey12 51 51 51 83 Grey13 34 34 34 84 Grey2 221 221 221 85 Grey11 68 68 68 86 Grey14 17 17 17 87 Black 0 0 0 255 TRANSPARENT 99 53 99 Default Font Styles and ID Numbers Font ID Font type Size Font...

Страница 123: ...le 185 Menu Bottom Rounded 145 Circle 195 Menu Bottom Rounded 155 Cursor Bottom Menu Bottom Rounded 165 Cursor Bottom with Hole Menu Bottom Rounded 175 Cursor Top Menu Bottom Rounded 185 Cursor Top wi...

Страница 124: ...unded 65 Neon Active S Menu Right Rounded 75 Neon Inactive L Menu Right Rounded 85 Neon Inactive S Menu Right Rounded 95 Oval V 30x60 Menu Right Rounded 105 Oval V 50x100 Menu Right Rounded 115 Oval V...

Страница 125: ...button to a standard page flip with page name Main Page BAT Append non unicode text Syntax BAT vt addr range button states range new text Variable variable text address range 1 4000 button states ran...

Страница 126: ...ue Variable variable text address range 1 4000 button states range 1 256 for multi state buttons 0 All states for General buttons 1 Off state and 2 On state color value Refer to theRGB Values for all...

Страница 127: ...ack type None Channel Invert On Always on Momentary and Blink Example SEND_COMMAND Panel BFB 500 Momentary Sets the Feedback type of the button to Momentary BIM Set the input mask for the specified ad...

Страница 128: ...e address 1 4000 source state 1 256 codes BM Picture Bitmap BR Border CB Border Color CF Fill Color CT Text Color EC Text effect color EF Text effect FT Font IC Icon JB Bitmap alignment JI Icon alignm...

Страница 129: ...he icon using values of 01 9900 icon numbers are assigned in the TPDesign4 Resource Manager tab Slots section I icon 01 9900 0 clear Set the icon using values of 01 9900 icon numbers are assigned in t...

Страница 130: ...ML max length Set the maximum length of a text area MK input mask Set the input mask of a text area VL 0 1 Log On Log Off the computer control connection VN network name Set network connection name V...

Страница 131: ...ess Example SEND_COMMAND Panel BNN 973 192 168 169 99 Sets the TakeNote button network name to 192 168 169 99 BNT Set the TakeNote network port for the specified Addresses Syntax BNT vt addr range net...

Страница 132: ...range 1 4000 button states range 1 256 for multi state buttons 0 All states for General buttons 1 Off state and 2 On state video state Video Off 0 and Video On 1 Example SEND_COMMAND Panel BOS 500 1...

Страница 133: ...ank the sound is then cleared If the sound name is not matched the button sound is not changed Syntax BSO vt addr range button states range sound name Variable variable text address range 1 4000 butto...

Страница 134: ...ge 1 256 for multi state buttons 0 All states for General buttons 1 Off state and 2 On state word wrap 0 Off and 1 On Default is Off Example SEND_COMMAND Panel BWW 500 1 1 Sets the word wrap on for th...

Страница 135: ...515 1 2 4 Sets the font size to font ID 4 for the On and Off states of buttons with the variable text range of 500 504 510 515 The Font ID is generated by TPD4 and is located in TPD4 through the Main...

Страница 136: ...n time Variable variable text address range 1 4000 bargraph ramp down time In 1 10th of a second intervals Example SEND_COMMAND Panel GRD 500 200 Changes the bargraph ramp down time to 20 seconds GRU...

Страница 137: ...tons with variable text ranges of 500 504 510 515 JSB Set bitmap picture alignment using a numeric keypad layout for those buttons with a defined address range The alignment of 0 is followed by left t...

Страница 138: ...ng a numeric keypad layout for those buttons with a defined address range The alignment of 0 is followed by left top The left and top coordinates are relative to the upper left corner of the button Sy...

Страница 139: ...110 Example SEND_COMMAND Panel TEC 500 504 510 515 1 2 12 Sets the text effect color to Very Light Yellow on buttons with variable text 500 504 and 510 515 TEF Set the text effect The Text Effect is s...

Страница 140: ...rd Drop Shadow 8 Glow X Soft Drop Shadow 1 with outline Outline S Soft Drop Shadow 2 with outline Outline M Soft Drop Shadow 3 with outline Outline L Soft Drop Shadow 4 with outline Outline X Soft Dro...

Страница 141: ...CUSTOM_EVENT TP 529 1012 ON state Fill Color CUSTOM_EVENT TP 529 1013 ON state Text Color CUSTOM_EVENT TP 529 1014 Border Name CUSTOM_EVENT TP 529 1015 Opacity Send_String 0 ButtonGet Id ITOA CUSTOM...

Страница 142: ...rmation The result sent to the Master would be ButtonGet Id 529 Type 1011 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT 222222FF TEXT LENGTH 9 BCF Get the current fill color Syntax BCF vt addr range button s...

Страница 143: ...information The result sent to Master would be ButtonGet Id 529 Type 1013 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT FFFFFEFF TEXT LENGTH 9 BMP Get the current bitmap name Syntax BMP vt addr range button...

Страница 144: ...Master would be ButtonGet Id 529 Type 1015 Flag 0 VALUE1 1 VALUE2 200 VALUE3 0 TEXT TEXT LENGTH 0 BRD Get the current border name Syntax BRD vt addr range button states range Variable variable text ad...

Страница 145: ...word wrap flag status information The result sent to the Master would be ButtonGet Id 529 Type 1010 Flag 0 VALUE1 1 VALUE2 1 VALUE3 0 TEXT TEXT LENGTH 0 FON Get the current font index Syntax FON vt ad...

Страница 146: ...rmation The result sent to the Master would be ButtonGet Id 529 Type 1003 Flag 0 VALUE1 2 VALUE2 12 VALUE3 0 TEXT TEXT LENGTH 0 JSB Get the current bitmap justification Syntax JSB vt addr range button...

Страница 147: ...ation information The result sent to the Master would be ButtonGet Id 529 Type 1006 Flag 0 VALUE1 1 VALUE2 6 VALUE3 0 TEXT TEXT LENGTH 0 JST Get the current text justification Syntax JST vt addr range...

Страница 148: ...ormation The result sent to the Master would be ButtonGet Id 529 Type 1009 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT 5088F2AE TEXT LENGTH 9 TEF Get the current text effect name Syntax TEF vt addr range b...

Страница 149: ...anel TXT 529 1 Gets the button OFF state text information The result sent to the Master would be ButtonGet Id 529 Type 1001 Flag 0 VALUE1 1 VALUE2 14 VALUE3 1 TEXT This is a test TEXT LENGTH 14 Panel...

Страница 150: ...2345 AKEYR Remove the Keyboard Keypad Remove keyboard or keypad that was displayed using AKEYB AKEYP PKEYP AKB AKP PKP EKP or TKP commands Syntax AKEYR Example SEND COMMAND Panel AKEYR Removes the Key...

Страница 151: ...ters Example SEND COMMAND Panel EKP 33333333 Enter Password Pops up the Keypad and initializes the text string 33333333 with prompt text Enter Password PKEYP Present a private keypad Pops up the keypa...

Страница 152: ...MMAND Panel SOU Music wav Plays the Music wav file TKP Present a telephone keypad Pops up the keypad icon and initializes the text string to that specified The Prompt Text is optional Syntax TKP initi...

Страница 153: ...AND Panel KPS 5 Sets the keyboard passthru to the Master Option 5 sends keystrokes directly to the Master via the Send Output String mechanism This process sends a virtual keystroke command VKS to the...

Страница 154: ...131 83 F1 132 84 F2 133 85 F3 134 86 F4 135 87 F5 136 88 F6 137 89 F7 138 8A F8 139 8B F9 140 8C F10 141 8D F11 142 8E F12 143 8F Num Lock 144 90 Caps Lock 145 91 Insert 146 92 Delete 147 93 Home 148...

Страница 155: ...Main Sets the page flip password to Main PWD Set the page flip password Password level is required and must be 1 4 Syntax PWD password level page flip password Variables password level 1 4 page flip p...

Страница 156: ...eded by a character any character contained in the URL must be escaped with a second character see example The file name field indicated by a F embedded code may contain special escape sequences as sh...

Страница 157: ...Sports_Image file name to test jpg and the path to Lab_Test Images Note that the 5F in the file path is actually encoded as 5F RSR Change the refresh rate for a given resource Syntax RSR resource nam...

Страница 158: ...ave pattern matching as part of their filename Neither newest file nor pattern matching apply to HTTP Dynamic Images When set the panel will first pull a list of files matching the given pattern from...

Страница 159: ...wavy lines across the entire screen This has been seen on middle resolutions and is referred to as the Mid Range Fallout problem This is due to the graphics controller settings in the firmware Update...

Страница 160: ...an NXA BASE B connected to a power supply NXT BP batteries can be charged from either an external NXT CHG battery charger or from within the NXA BASE B located below an NXT panel The NXA BASE B Batte...

Страница 161: ...vices such as Modero panels can be associated for use with a single Master Each Modero panel comes with a defaulted Device Number value of 10001 When using multiple panels it can become very easy to o...

Страница 162: ...t is still pro viding power Launch the updated Studio 2 4 Refresh the particular System from within the OnLine Tree tab Identify the NXT panel using the battery base From the Main menu go to Tools Fir...

Страница 163: ...xt Code Inputs Code Bargraph Multi State Bargraph P Display the current percentage of the bargraph derived from the Adjusted Level Value as it falls between the Range Values Display the current percen...

Страница 164: ...area Suggest proper format with fixed characters Right to Left Required or Optional Change Force a Case Create multiple logical fields Specify range of characters number for each field Limit you to a...

Страница 165: ...lied the behavior of the keyboard needs to change to accommodate the input mask s requirement When working with masks any literal characters in the mask will be skipped by any cursor movement includin...

Страница 166: ...screte feedback for AM and PM Input mask output examples The following are some common input masking examples URL Resources A URL can be broken into several parts For example the URL http www amx com...

Страница 167: ...ces that code with a particular piece of panel button or state information For example http www amx com img asp device DV would become http www amx com img asp device 10001 Other used escape sequences...

Страница 168: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...

Отзывы: