Setup Pages and Descriptions
52
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
System Settings Page (Cont.)
IP Settings: (Cont.)
MAC Address:
Displays a read-only field that is factory set by AMX for the built-in Ethernet interface.
Master Connection:
Sets the NetLinx Master communication values:
Type:
Sets the NetLinx Master to communicate with the panel via either USB or
Ethernet. This is based on the cable connection from the rear. The Type field is read-only
and cannot be set.
ICSNet is not a supported option on this panel.
•
Ethernet
is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector) used to
network computers together and is used in most LAN (local area networks). This
description is also used to refer to both wired and wireless communication.
•
USB
is a connection through the mini-USB port to a host computer.
Mode:
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
•
URL
- In this mode, enter the IP/URL, Master Port Number, and username/password (if
used) on the Master.
- The System Number field is read-only because the panel obtains this information from
the communicating Master.
•
Listen
- In this mode, add the Modero panel address into the URL List in NetLinx Studio
and set the connection mode to Listen. This mode allows the Modero touch panel to
"listen" for the Master’s communication signals.
- The System Number and Master IP/URL fields are red-only.
•
Auto
- In this mode, enter the System Number and a username/password (if
applicable). This mode is used when both the panel and the NetLinx Master are on the
same Subnet and the Master has its UDP feature enabled.
- Master IP/URL field is read-only.
System Number:
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Master IP/URL:
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Master Port Number:
Enters the port number used with the NetLinx Master.
• Default value is 1319.
(ETHERNET Only - disabled when USB is selected)
Username/Password:
If the target Master has been previously secured, enter the alphanumeric string (into each
field) assigned to a pre-configured user profile on the Master. This profile should have the
pre-defined level of access/configuration rights.
USB IP Settings:
Sets IP settings through the mini-USB port.
DHCP/Static:
Switches between HDHCP and Static connections.
IP Address:
The IP address of the device
Содержание Modero NXD-500i
Страница 4: ......
Страница 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Страница 30: ...NXD 500i Touch Panel Accessories 18 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 140: ...Appendix A Text Formatting Codes 128 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 143: ...Appendix B Complex Script Support 131 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...