Configuring Communication
31
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
Master Connection Section - NetLinx Master Ethernet IP Address - URL Mode
In this mode, enter the System Number (
zero
for an unknown System Number) and the IP/URL of the Master (the
Master Port Number is defaulted to
1319
).
1.
In the
System Settings
page, press the
Mode
field until the choice cycles to
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls this value
directly from the communicating target Master, virtual or not. A Virtual Master system value can be set
within the active AMX software applications such as NetLinx Studio, TPD4, or IREdit.
2.
Press the
Master IP/URL
field to open a Keyboard and enter the Master IP Address
obtained from the
Diagnostics -
Networking Address
dialog of the NetLinx Studio application.
3.
Click
Done
to accept the new value and return to the
System Connection
page.
4.
Do not alter the Master Port Number value. This is the default value used by NetLinx.
5.
Enter a username and password (
into their respective fields
) if the target Master has been previously secured.
6.
Press the
Back
button to return to the
Protected Setup
page.
Master Connection Section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, add the Modero panel IP Address into the URL List of the Master by using NetLinx Studio. This mode sets
the Modero panel to "listen" for broadcasts from the Master (using the panel IP from its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address from the IP
Settings of the System Connection page.
The
DHCP/Static
field, in the
IP Settings
section of the
System Settings
page, must be set to
DHCP
to get
Dynamic IP information for the panel.
Press the on-screen
Reboot
(from the
Protected Setup
page) to save any changes and restart the panel.
After power-up, press the front button for
3 seconds
to access the
Setup
page.
Navigate to the
Setup > Protected Setup > System Settings
page and note the newly obtained Dynamic IP
Address information from the
IP Settings
section. This information is then entered into the URL List for the
connected NetLinx Master.
2.
Toggle the
Type
field until
Ethernet
is selected (
from the Master Connection section of the System Connection
page
).
3.
Press the
Mode
field (to set the connection Mode) until the choice cycles to
Listen
. The
System Number
and
Master
IP/URL
fields are then greyed out.
4.
Enter a username and password into their respective fields if the target Master has been previously secured.
5.
Select the
OnLine Tree
tab from the
Workspace
window.
6.
Enter the
System
and
Device
number for the specific Master associated with the touch panel as seen in the
OnLine
Tree
tab.
7.
Click
Add
and enter the IP Address of the Modero touch panel into the
Add URL
dialog.
8.
Click
OK
to enter the IP Address and add it to the list.
9.
Click
Done
when finished adding your panel information to the list.
Master Connection Section - NetLinx Master Ethernet IP Address - Auto Mode
In this mode, enter the System Number of the NetLinx Master.
This mode instructs the Modero to search for a Master that uses the same System Number (assigned within the
Master
Connection
section) and
resides on the same Subnet as itself.
1.
In the
System Settings
page, press the
Mode
field until the choice cycles to the word
Auto
.
2.
Press the
System Number
field to launch a Keypad and enter the value for the system number of the NetLinx Master.
This value can be obtained from the
NetLinx Studio program > OnLine Tree
of the Workspace window.
3.
Do not alter the
IP Settings
section of the
System Settings
page, as these fields are not applicable to this connection
mode.
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number from
within the Device Addressing dialog is correctly assigned.
Содержание Modero NXD-500i
Страница 4: ......
Страница 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Страница 30: ...NXD 500i Touch Panel Accessories 18 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 140: ...Appendix A Text Formatting Codes 128 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 143: ...Appendix B Complex Script Support 131 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...