Programming
65
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
Programming
Overview
The NXD-500i may be programmed, using the commands in this section, to perform a wide variety of operations using
Send_Commands and variable text commands.
A device must first be defined in the NetLinx programming language with values for the Device: Port: System
In all programming examples -
Panel
is used in place of these values and represents all Modero panels).
Button Assignments
Page Commands
These Page Commands are used in NetLinx Programming Language and are case insensitive.
Verify that you are using the latest NetLinx Master and Modero firmware, and verify
that you are using the latest version of NetLinx Studio and TPD4.
• Button Channel Range: 1 - 4000 Button push and Feedback (per address port)
• Button Variable Text range: 1 - 4000 (per address port)
• Button States Range: 1 - 256 (0 = All states, for General buttons 1 = Off state and 2 = On state).
• Level Range: 1 - 600 (Default level value 0 - 255, can be set up to 1 - 65535)
• Address port Range: 1 - 100
These button assignments can only be adjusted in TPD4 and not on the panels
themselves.
Page Commands
@APG
Add the popup page to a specified popup group, if it does not already exist.
If the new popup is added to a group which has a popup displayed on the current page along with the new
pop-up, the displayed popup will be hidden and the new popup will be displayed.
Syntax:
"'@APG-<popup page name>;<popup group name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
popup group name = 1 - 50 ASCII characters. Name of the popup group.
Example:
SEND_COMMAND Panel,"'@APG-Popup1;Group1'"
Adds the popup page ’Popup1’ to the popup group ’Group1’.
@CPG
Clear all popup pages from specified popup group.
Syntax:
"'@CPG-<popup group name>'"
Variable:
popup group name = 1 - 50 ASCII characters. Name of the popup group.
Example:
SEND_COMMAND Panel,"'@CPG-Group1'"
Clears all popup pages from the popup group ’Group1’.
Содержание Modero NXD-500i
Страница 4: ......
Страница 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Страница 30: ...NXD 500i Touch Panel Accessories 18 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 140: ...Appendix A Text Formatting Codes 128 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 143: ...Appendix B Complex Script Support 131 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...