Configuring Communication
32
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
4.
Enter a username and password into their respective fields if the target Master has been previously secured.
5.
Press the
Back
button to open the
Setup
page and confirm an active connection.
Using G4 Web Control to Interact with a G4 Panel
The
G4 Web Control
feature allows a PC to interact with a G4-enabled panel via the web. This feature works in tandem
with the browser-capable NetLinx Security firmware update (
build 300 or higher
). G4 Web Control is only available
with the latest Modero panel firmware. Refer to the
G4 Web Control Settings Page
section on page 53 for more detailed
information on G4 Web control.
1.
Press the
Front Setup Access
button for 3 seconds to open the
Setup
page.
2.
Press the
Protected Setup
button located on the lower-left of the panel page to open the
Protected Setup
page and
display an on-screen keypad.
3.
Enter
1988
into the Keypad’s password field (
1988
is the default password
) and press
Done
when finished.
4.
Press the
G4 WebControl
button to open the
G4 Web Control
page (FIG. 28).
5.
Press the
Enable/Enabled
button until it toggles to
Enabled
(
light blue color
).
6.
The
Network Interface Select
field is read-only and displays the method of communication to the web. Verify the
selection of the proper interface connection, as this field does not auto-detect the connection type being used (
see
below
).
Wired
is used when a direct Ethernet connection is being used for communication to the web. This is the
default setting if no wireless interface card is detected or if both an Ethernet and wireless card connection is
detected by the panel.
Wireless
is used when a wireless card is detected within the internal card slot. The NXD-500i panel does not
provide wireless communication, so this option is not available.
7.
Press the
Web Control Name
field to open the
Web Name
keyboard.
The NetLinx Master and the Modero panel must both be on the same Subnet.
Verify that the NetLinx Master (ME260/64 or NI-Series) has been installed with the
latest firmware KIT file from
www.amx.com
.
Refer to the NetLinx Master instruction manual for more detailed information on the
use of the new web-based NetLinx Security.
Clearing Password #5, from the initial Password Setup page, removes the need to
enter the default password before accessing the Protected Setup page.
FIG. 28
G4 Web Control page
Содержание Modero NXD-500i
Страница 4: ......
Страница 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Страница 30: ...NXD 500i Touch Panel Accessories 18 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 140: ...Appendix A Text Formatting Codes 128 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 143: ...Appendix B Complex Script Support 131 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...