Installation
6
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
4.
Place the Faceplate back onto the device. Make sure to align the Microphone, Light, and PIR Motion sensor
locations on the device to their respective openings on the Faceplate assembly.
Installing the NXD-500i Touch Panel
The NXD-500i can be installed either directly into the (optional) CB-TP5i Rough-In Box or other solid surface
environment, using solid surface screws or the included locking tabs as mounting options.
The following sections describe mounting the touch panel directly into a pre-wall rough-in box, a solid surface, drywall,
or an NXA-RK5 Rack Mount Kit.
Pre-Wall Installation of the Rough-In Box
The CB-TP5i Rough-In Box (
FG038-11
) is an optional metallic box that is secured onto a stud/beam in a
pre-wall
setting, where no walls are present.
Installation procedures and configurations can vary, depending on the installation environment. This section describes
the installation procedures for the most common installation scenarios.
1.
Attach the optional Back Cover for the CB-TP5i (
FG038-12
) if necessary.
2.
Fasten the CB-TP5i Rough-In Box to the stud through the holes on the Stud Mounting tabs (FIG. 4), using either
nails or screws.
3.
Remove the appropriate wiring knockouts from the rough-in box (FIG. 4) to accommodate the cables being
threaded through to the NXD-500i touch panel.
4.
Thread the incoming Ethernet and USB wiring through the knockouts. Use of the left wiring knockouts are
recommended with this installation. Leave enough slack in the wiring to accommodate any re-positioning of the
panel.
In order to guarantee a stable installation of the NXD-500i, the distance between the
CB-TP5i and the outer wall surface must be a minimum of .50 inches (1.27cm) and a
maximum of .875 inches (2.22cm).
Cutting out the surface slightly smaller than what is outlined in the installation
drawings, to allow any necessary cutout adjustments, is highly recommended.
FIG. 4
CB-TP5i Rough-In Box components
Stud
Stud Mounting tabs
Wiring knockouts
Содержание Modero NXD-500i
Страница 4: ......
Страница 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Страница 30: ...NXD 500i Touch Panel Accessories 18 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 140: ...Appendix A Text Formatting Codes 128 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Страница 143: ...Appendix B Complex Script Support 131 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...