DAVINO 120TW - USER AND MAINTENANCE MANUAL Rev.04
- Pag. 96
13.9
OPERATIONS EVERY 1000 HRS
HYDRAULIC FLUID REPLACEMENT
Make sure the machine is parked on a flat area and the motor is shutdown.
Remove upper cap
Drain the oil completely from the tank using the botton plug into a pre-assembled
container.
To empty tank, tighten bottom cap and fill the reservoir with prescribed oil unit it reaches
the level highlighted by the plug level rod.
Avoid environmental pollution. Store old oils and
lubricants in adeguate containers and consign them to
authorized companies for the treatment of harmful and
polluting waste
Use only lubricating oil recommended by the manufacturer and suggested
in the lubricant table
AXLE AND GEAR OIL CHANGE
Bring the machine on level ground.
Turn off the engine and insert the parking brake.
Place two containers under the front and rear axles.
Unscrew the drain plugs of the differentials and planetary gearboxes, taking care to bring for every planetary
gearbox the oil level / drain plug in the lower position (by rotation).
Unscrew the drain plugs.
Make the oil flow out.
Reinstall the drain plugs.
Reintroduce the oil of the expected type by a syringe until it drips from the loading holes.
Reinstall the filler plugs to the correct locking.
Use only lubricating oil recommended by the manufacturer and suggested
in the lubricant table.
Avoid environmental contamination. Store used oil in suitable containers
and deliver to the companies authorized by the consortium in charge of the
recovery of waste oils.
.