A-8 | Thermox Series 2000 WDG-IV /I VC / IVCM
02/02
Config_flags
IQ
System configuration flags (1=true,
0=false)
bit 0
– relays energize on alarm. If not,
they deenergize.
Bit 1
– auto calibration time is set, an
auto calibration will happen at the set
time if the auto calibration is enabled
bit 2
– auto calibration timer is enabled,
since this is enabled, an auto calibration
will occur at the auto calibration time.
bit 3
– real time clock is set.
bit 4
– Step Function enabled (only for
RSS)
bit 5
– auto verify time is set, an auto
verify will happen at the set time if the
auto verify is enabled.
bit 6
– auto verify timer is enabled, if
this is enabled an auto verify will occur
at the auto verify time.
bit 7
– auto calibration cycle is
programmed in hours, 0 if in days
bit 8
– auto verify cycle time is
programmed in hours, 0 if in days
bit 9
– Future use (used on S2000)
bit 10
– Future use (used on S2000)
bit 11
– Future use (used on S2000)
bit 12
– Future use (used on S2000)
bit 13
– Future use (used on S2000)
bit 14
– WDG type sensor, 0 is HP type
sensor
bit 15
– combustibles are measure in
percent,0 = combustibles are measured in
PPM
R/W
Содержание Thermox Series 2000 WDG-IV
Страница 14: ...xiv Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 32: ...2 8 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 59: ...Installation 3 27 Figure 3 20 Sensor connections with all sensor options ...
Страница 67: ...Installation 3 35 Figure 3 24 Series 2000 2 wire RS 485 communication connections ...
Страница 69: ...Installation 3 37 Figure 3 25 Series 2000 4 wire RS 485 communication connections ...
Страница 72: ...3 40 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 100: ...4 28 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 126: ...5 26 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 143: ...Service and Parts 7 3 Figure 7 1 Wiring diagram for standard sensor ...
Страница 145: ...Service and Parts 7 5 Figure 7 2 Cell replacement ...
Страница 155: ...7 15 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 181: ...A 26 Thermox Series 2000 WDG IV I VC IVCM This page intentionally left blank ...
Страница 185: ...B 4 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...
Страница 191: ...D 2 Thermox Series 2000 WDG IV IVC IVCM This page intentionally left blank ...