Maintenance, repair and care
Citan BAG0014.4 09.14
135
12.9
Setting the track width (activation and deactivation of shutters)
With the increasing number of tramline coulters arranged side by side
the bout width of the tramline increases.
6 tramline coulters can be connected to one distributor head.
The shutters close the feed tubes of the tramline coulters.
Deactivate the shutters (Fig. 144/2) when not in use. Deactivated
shutters do not close the feed tubes of the tramline coulters. .
Always activate and deactivate the shutters in pairs, always two op-
posite shutters on the base plate.
Warning!
The distributor head is located in the centre of the machine.
Apply the parking brake, stop the tractor engine and remove the
ignition key.
Before stepping on, clean the way towards the distributor head
and within the range of the distributor head (danger of slipping).
Danger on the way towards the distributor head and within the
area of the distributor head.
Das Schieber aktivieren / deaktivieren ist einfacher bei betätigter
Fahrgassenschaltung.
→
Position der Schieber ist sichtbar!
Activate or deactivate the shutters:
1. Apply the parking brake, stop the tractor
engine and remove the ignition key.
2. Switch off the AMATRON 3.
3. Remove the distributor outer hood (Fig.
143/1) d.
4. Remove the ring (Fig. 143/2).
5. Remove the distributor inner hood (Fig.
143/3).
6. Remove the foam rubber insert (Fig. 143/4).
Fig. 143
7. Slacken the bolts (Fig. 144/1) n.
8. Remove the shutter tunnel (Fig. 144/2).
Activation of shutter:
9. The shutter (Fig. 144/3) is positioned in the
guide way as illustrated.
Deactivation of shutter:
10. Turn the shutter (Fig. 144/3) and insert into
the hole (Fig. 144/4).
11. Bolt the shutter tunnel (/2) onto the base
plate.
Fig. 144