Faults
Citan BAG0014.4 09.14
117
11.5
Table of faults
Fault
Possible cause
Remedy
Track marker does not change
Sensor operational position has
been set wrongly
Adjust the sensor
Sensor operational position is
defective
Exchange sensor operational
position
Hydr. valve has got stuck
Exchange hydr. valve
Track marker shifts too early or
too late
Wrong setting of sensor opera-
tional position
Adjust the sensor
Tramlinc bout counter does not
work
AMATRON 3: Actuate the
STOP key
Switch off the STOP key
Tramline rhythm wrong
Adjust the tramline rhythm
The sensor operational position
is defective
Exchange the sensor operational
position
Wrong sensor adjustment
Adjust the sensor
AMATRON 3: Blower fan sensor
triggers an alarm
Wrong setting of alarm trigger
limit
Change the alarm trigger limit
Oil volume too high or too low
Adjust the oil volume
The sensor blower fan is defec-
tive
Exchange the sensor blower fan
Forward speed sensor (star
wheel / Vario gearbox) without
any function
Forward speed sensor is defec-
tive
Exchange the forward speed
sensor
Shutters within the distributor
head (tramline shifting) do not
work
Dressing agent or dust inside the
tramline shutter slide
Clean the distributor head
Dressing agent or dust between
distributor head and control disc
Clean the control disc
Automatic safety reacts
•
Switch off AMATRON 3 and
switch on again. The safety
device should work properly
now.
•
Clean the distributor head