Installation Codes & Standards
The following codes and standards are required for installation
of this appliance: air supply, electrical connections, water
connections, and waste water discharge.
NOTICE:
Where automatically operated appliances are
vented through a ventilating hood or exhaust
system equipped with a damper or with a power
means of exhaust, provisions shall be made to
allow the equipment to operate only when the
damper is open to a position to properly vent the
appliance and when the power means of exhaust is
in operation.
IN ACCORDANCE WITH NFPA 54
COMMONWEALTH OF MASSACHUSETTS ONLY
Ventilation Requirements
Authorities having jurisdiction should be consulted as to the
requirements for this equipment with respect to ventilation
and fire extinguishing systems to ensure conformity with
any Federal, State, or local installation codes.
Microphone
Position
Sound Pressure Level dBA
With Hood
System
Operating
Without
Hood System
Operating
Front
70
59
Right Side
69
58
Left Side
70
60
Rear
69
60
Sound Pressure Measurement
WARNING
Improper installation, alteration, adjustment, service,
cleaning, or maintenance could result in property
damage, severe injury, or death.
Read and understand the installation, operating and
maintenance instructions thoroughly before installing,
servicing, or operating this equipment.