MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual 21
CAUTION
Power source must match voltage identified
on appliance rating tag. The rating tag
provides essential technical information
required for any appliance installation,
maintenance or repairs. Do not remove,
damage or modify the rating tag.
WARNING
To prevent serious injury, death, or
property damage:
All electrical connections must be
made by a qualified and trained service
technician in accordance with applicable
electrical codes.
This appliance must be adequately
grounded in accordance with local
electrical codes or, in the absence of local
codes, with the current edition of the
National Electrical Code ANSI/NFPA No.
70. In Canada, all electrical connections
are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1 or
local codes.
CE-approved appliances include an
equipotential-bonding terminal marked
with the symbol shown on the left .
Provisions for earthing are to be made in
accordance with IEC:2010 60335-1 section
27 or local codes.
WARNING
Improper installation, alteration, adjustment, service,
cleaning, or maintenance could result in property
damage, severe injury, or death.
Read and understand the installation, operating and
maintenance instructions thoroughly before installing,
servicing, or operating this equipment.
WARNING
Appliances without a cord provided by the
factory must be equipped with a cord of
suff icient length to permit the appliance to
be moved for cleaning.
Always use the correct AWG wire size
based on the electrical requirements for
the appliance.
Hard wired models:
Hard wired models must be equipped with a country certifi ed
external allpole disconnection switch with suffi cient contact
separation.
If a power cord is used for the connection of the product an
oil resistant cord like H05RN or H07RN or equivalent must be
used.
1. An electrical wiring diagram is located behind the control
panel on the left side of the appliance. 3-phase appliances
must be branch circuit protected with proper ampacities, in
accordance with the wiring diagram. A dedicated 30 Amp
breaker is required.
2 Ground fault or residual current protection device must
accommodate a leakage current of 20mA
3. Wire size for the main incoming power to the appliance
must match the minimum size listed in the specifications.
For supply connections, locate the wire size posted on the
label located on the electrical control box cover, behind the
service panel.
4. When connecting to a Delta-B (wild leg) on a 3-phase
system, the wild leg must be connected to line 3. Install
wiring with a strain relief.
5. Before operating the appliance, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NOTICE:
After both water and electrical connections have
been completed, operate the appliance in any
cooking mode for a period of 15 minutes and
recheck the main power connections at the
terminal block to make certain they remain tight.
380-415V:
WARNING
For CE approved appliances:
To prevent an electrical
shock hazard between the appliance and other appliances or
metal parts in close vicinity, an equalization-bonding stud is
provided. An equalization-bonding lead must be connected
to this stud and the other appliances/metal parts to provide
suff icient protection against potential diff erence.
The terminal is marked with the following symbol.
Provisions for earthing are to be made in accordance
with IEC:2010 60335-1 section 27 or local codes.