Installation
24
MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual
Electrical Kit Installation - 60 Hz
2
3
4
5
1
B
A
B
A
1
2
3
4
3
1
2
4
Applications for the Americas
Power supply side
Appliance side
Remove enough cable covering so the wires reach the terminal strip.
Depending on the application, install the straight or elbow fitting to the cable.
3 PH Chassis
1 PH Chassis
Cut threads into nut before installing fitting. To do so,
apply a light lubricant and thread nut on and off fitting.
BK RD OR GR
BK WH*
*Also referred
to as neutral
GR
1/2"
(12mm)
1/2"
(12mm)
28mm (ID) x 44mm (OD) adapters
(included in installation kit) –
use if needed