Installation
22
MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual
Mobile Equipment Restraint
Any appliance that is not furnished with a power supply
cord but includes a set of casters, stand with casters,
or a stacked configuration must be installed with a
tether. Adequate means must be provided to limit
the movement of this appliance without depending
on or transmitting stress to the electrical conduit. The
following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must be the locking type.
3. Such appliances must be installed with the use of a
flexible connector secured to the building structure.
4. Each of the stacked appliances must be installed
with the use of a flexible connector secured to the
building structure. A single wall anchor may be used.
A mounting connector for a restraining device is located
on the top right back panel of the appliance chassis or
on an appliance stand, approximately 18" (457mm) from
the floor. A flexible connector is not supplied by nor is it
available from the factory.
WARNING
RISK OF ELECTRIC SHOCK
Appliance must be secured to building
structure. Failure to observe this precaution
may result in damage to the equipment and
severe personal injury.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
LEFT SIDE VIEW
REAR VIEW
Mounting connector
for restraining device
WARNING
To prevent
SERIOUS INJURY, DEATH or
PROPERTY DAMAGE:
All electrical connections must be made
by a qualifi ed and trained service
technician in accordance with applicable
electrical codes.
WARNING
To prevent serious injury, death, or
property damage:
All electrical connections must be
made by a qualified and trained service
technician in accordance with applicable
electrical codes.
This appliance must be adequately
grounded in accordance with local
electrical codes or, in the absence of local
codes, with the current edition of the
National Electrical Code ANSI/NFPA No.
70. In Canada, all electrical connections
are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1 or
local codes.
CE-approved appliances include an
equipotential-bonding terminal marked
with the symbol shown on the left .
Provisions for earthing are to be made in
accordance with IEC:2010 60335-1 section
27 or local codes.
Top/Back of Appliance
L1
L2
L3
EQUIPOTENTIAL GROUND SCREW
220-240V, 1PH & 380-415V
INCOMING ELECTRICAL TERMINALS
APPLIES TO 208-240V & 380-415V UNITS
CUSTOMER MUST SUPPLY CORD
INTERNAL
GROUND STUD
N
GROUND