Installation
18
MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual
NOTICE:
• Note dimensions required for doorways and
aisles for access of the appliance and pallet to
the installation site. Transport the appliance in
an upright and level position only. Do not tilt
the appliance.
• To avoid equipment damage, observe
attention label on appliance for area to avoid
with lifting fork.
Positioning On Site
Place the Combitherm appliance on a stable,
non‑combustible, level horizontal floor.
It is strongly recommended that table top models be
mounted on a factory supplied stand or a stand that
is stable, open, and level. Recommended height is
32" (813mm).
Air supply vents are located at the
bottom of the appliance and must not be blocked
when mounted on a stand
To insure proper operation, the installation of this appliance
must be completed by qualified technicians in accordance
with the instructions provided in this manual. Failure to
follow the instructions provided may result in damage
to the appliance, building, or cause personal injury to
personnel.
NOTICE:
• Additional clearance is needed for service access.
A minimum distance of 18" (457mm) is strongly
recommended. If adequate service clearance is
not provided, it will be necessary to disconnect
the water and drain to move the appliance with a
fork lift for service access. Charges in connection
with inadequate service access is not covered
under warranty.
• Do not install directly over a drain. Steam rising
up out of the drain will adversely affect operation,
interrupt cooling air circulation, and damage
electrical and electronic components.
WARNING
To prevent serious injury, death, or property damage:
• Always keep appliance on top of a pallet when using a
fork lift or a pallet lift truck to move appliance.
• Always use a suff icient number of trained and
experienced workers to place the appliance on floor,
stand, or counter.
WARNING
To prevent personal injury, death or
property damage:
Do not store or use gasoline or other
fl ammable vapors or liquids in the vicinity
of this or any other appliance.
Minimum Clearance Requirements
Left Side
4" (102mm) minimum
18" (457mm) service access recommended
Right Side
4" (102mm)
Back
4" (102mm) for plumbing
Bottom
4" (102mm) for air movement
Top
20" (508mm) for air movement