Installation
20
MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual
Positioning Requirements
□ In order to ensure proper ventilation, a minimum distance
of at least 4" (102mm) must be kept from the sides of the
appliance and any adjoining surfaces.
NOTE:
Additional clearance is needed for service access.
A minimum distance of 18" (457mm) is strongly
recommended. If adequate service clearance is not
provided, it will be necessary to disconnect the water,
and drain to move the appliance with a fork lift for
service access. Charges in connection with inadequate
service access is not covered under warranty.
□ Allow a minimum of 4" (102mm) from the right side of the
appliance to allow the door to open to at least a 90° angle.
Fully opened, the door will extend up to a 225° angle.
□ Allow a minimum clearance of 4" (102mm) from the back of
the appliance for plumbing connections.
□ Allow a 20" (508mm) clearance at the top of the appliance for
free air movement and for the steam vent(s) located at the
top.
□ Do not install the appliance adjacent to heat producing
equipment such as fryers, broilers, etc. Heat from
such appliances may cause damage to the controls of
the Combitherm. Minimum clearance recommended:
20" (508mm)
Place the
Combitherm
appliance on
a stable, non-
combustible level
horizontal surface. For countertop models, the appliance stand
must be level. Level from front-to-back and side-to-side by
means of the adjustable legs. In addition, the overall height of
the appliance should be positioned so the operating controls
and shelves may be conveniently reached from the front.
37-3/16
" (945mm)
7-1/8" (181mm)
3-1/16
" (77mm)
44-1/4
" (1
124mm)
14-7/8
" (377mm)
22-1/4" (565mm)
17-1/4" (438mm)
6-3/8
" (162mm)
37-1/4" (946mm)
31-9/16" (802mm)
29-9/16" (675mm)
47-3/4
" (1213mm)
18-5/16
" (464mm)
21-3/4" (552mm)
17-1/4"
(438mm)
31-1/16" (789mm)
26-9/16" (675mm)
9-5/16
" (236mm)
Stand Installation
1) Remove the legs from the CT Express.
2) Carefully lift and set the CT Express on the stand.
3) Position the appliance to make sure the sides and back are
positioned flush to the stand. Flush the sides and back of CT
Express and stand.
4) Secure the CT Express to the stand in four places with
screws and Lock Washers.
The stand has adjustable legs for leveling purposes. Stand legs
must be bolted to the floor. Air supply vents are located at the
bottom of the appliance and must not be blocked when mounted
on a stand.
EXHAUST VENT
18"
(457mm)
4"
(102mm)
4" (102mm)
20"
(508mm)
MINIMUM
20"
(508mm)
Содержание CT Express Combitherm CTX4-10E
Страница 14: ...This page intentionally left blank...
Страница 27: ...Installation MN 29805 Rev 11 07 18 Combitherm CT Express Installation Manual 27 a b c d e f h i j g...
Страница 29: ...Installation MN 29805 Rev 11 07 18 Combitherm CT Express Installation Manual 29 a b d e g h i f c 45 45 90 90...
Страница 52: ...CT Express...