Installation
MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual 33
1. Charcoal Filter: The charcoal fi lter should be
inspected for contaminant's on a regular basis.
Replacement must be made at a minimum of three
month intervals — more oft en if heavy contaminant's
are visible or if the fi lter no longer controls odors.
To remove the charcoal fi lter, pull and slide out. When
replacing the fi lter, ensure that the fi lter clip is in place
at rear of the fi lter. Make certain the air fl ow arrow(s)
point toward the hood fan (back of the appliance), and
that the fi lter is replaced using the fi lter track in the
metal back plate provided with the hood.
FI-24114
2. Grease Filter: Cleaning frequency should be based
on appliance usage with a maximum of two weeks
between cleaning if the appliance is used for non-
grease laden products or steam applications only.
Grease laden products require cleaning frequency of at
least once a week.
Remove the grease fi lter by pulling it straight out
of the housing. Place the fi lter in the dishwasher
or wash separately by placing in hot, soapy water
until all grease and particles have been removed.
Rinse thoroughly. Allow the fi lter to air dry
before reinstalling.
To replace the grease fi lter, the metal handles on
the fi lter casing should be facing toward the front of
the appliance.
FI-24113
Top Exhaust Vent
2
1
Filter Track
Filter Switch
Ventless Hood Model