![Algema BLITZLADER 2 Скачать руководство пользователя страница 93](http://html1.mh-extra.com/html/algema/blitzlader-2/blitzlader-2_operating-instructions-manual_2896112093.webp)
7 Additional information
7.4 Maintenance list
Eder GmbH
92 / 108
Operating Instructions Algema Blitzlader 2 Air - Edition 04/2021
Each equipment operator enters the maintenance work performed here and confirms it
with date and signature. The scope of the maintenance work can be found in the table (
see
"Overview of the maintenance to be performed regularly ", page 65
).
Scope
(mark with a cross where
applicable)
Maintenance on
Signature of
the equipment
operator
semiannual
o. 10.000 km
annual
Eder GmbH
7.5 Troubleshooting assistance
7 Additional information
Operating Instructions Algema Blitzlader 2 Air - Edition 04/2021
93 / 108
Error
Cause
Remedy
Chapter
Control does not
respond or does
not respond to
several functions
Fuse defective
Check fuses
see "Fuses", page
84
Body functions
cannot be
switched on at the
touch panel in the
driver's cab.
Parking brake
not applied
Activate parking
brake
See "Tilt plateau
operation ", page
21
Ignition of the car
transporter off
Switch on ignition
See "Tilt plateau
operation ", page
21
Plateau does not
tilt up or does not
tilt up completely
Discharge
vehicle battery
Start the engine, if
necessary start it
externally
Operating
instructions base
vehicle
Set-up functions
are not switched
on
Switching on the
setup functions on
the touch panel
See "Tilt plateau
operation ", page
21
Function for manual
control or radio
remote control not
selected correctly
Activate the function
of the manual
control or radio
remote control as
desired.
See "Tilt plateau
operation ", page
21
The sensor end
position tilt shear
switches off the
electro-hydraulics
Check settings,
control LEDs must
not light up as long
as the tilting shear
has not yet reached
the end position.
see pictures below
sensors
The tilt sensors
switch off the
electrohydraulics
even though the
rear of the plateau
does not touch the
ground.
Check free
movement and
setting, control
LEDs on the sensor
must not light up as
long as the plateau
on the board is not
yet in place.
see "Lubricating and
greasing moving
parts", page 79
see pictures below
sensors
Oil level of electro-
hydraulics too low
Check oil level and
top up if necessary
see "Checking the
oil level and oil
change", page 77
Содержание BLITZLADER 2
Страница 1: ...Operating instructions BLITZLADER 2 WITH AIR SUSPENSION ALGEMA FIT ZEL Brands of EDER GmbH ...
Страница 40: ......
Страница 52: ......
Страница 105: ...Eder GmbH 9 Notes 9 Notes Operating Instructions Algema Blitzlader 2 Air Edition 04 2021 105 108 ...
Страница 106: ...9 Notes Eder GmbH 106 108 Operating Instructions Algema Blitzlader 2 Air Edition 04 2021 ...
Страница 107: ...Eder GmbH 9 Notes Operating Instructions Algema Blitzlader 2 Air Edition 04 2021 107 108 ...