Manual
TdC 8001
-78-
−
display (1) must show correct start number (and group)
−
start impulse for number 1 effected
−
display (5) now shows running time, display (6) the started start number
−
display (1) changes automatically to next start number
−
when the competitor triggers the finish photocell, the running time is displayed; the time of day
is printed with run time and speed
−
start impulse for number 2 effected
−
display (5) now shows running time, display (6) started start number
−
display (1) changes automatically to next start number
−
when the competitor triggers the finish photocell, the rinning time is displayed; time of day is
printed with run time and speed
−
etc.
When start number automatic is set to START, only one competitor must be on the course.
Channel assignment
c0 = start channel
c1 = finish channel
c2 = no function
c3 = no function
c4 = no function
c5 = no function
c6 = no function
c7 = no function
c8 = no function
c9 = no function
Default main menu:
Menu 1:
delay time start
= 1.0 sec.
Menu 2:
delay time finish
= 0.3 sec.
Menu 3:
seconds mode
= off
Menu 4:
display time 1
= 3 sec.
Menu 6:
display thousandths
= off
Menu 7:
info display
= finish
Menu 9:
running tenth
= off
Menu 11: run time rank
= on
Menu 12: start number automatic
= off
Menu 13: automatic time
= 00:00:00.00
Menu 14: print start time
= off
Menu 16: paperfeed
= 0
Menu 17: RS232 baud rate
= 9600 baud
Menu 18: RS232 run time
= off
Menu 19: d-board baud rate
= 2400 baud
Menu 20: d-board channel 2
= running
Menu 21: beep
= on
Menu 23: groups
= off
Menu 25: change race
Menu 26: d-board test
Menü 32: distance
= 100 m
Menu 53: bib-counting
= manual
Menu 55: LED-brightness
= 9
Menu 56: delaytime to next StNo
= 3
Menu 59: pulse from radio
= all channels off
Menu 62: extern beep
= all channels off
Menu 63: RS485 user
= Wireless TN (WTN)
Printer: example of printout
0001 ST
11:47:59.9965
start time (1
st
photocell)
FT
11:48:02.0775
finish time (2
nd
photocell)
RT
0:02.081
run time
SP km/h
172.99
speed in km/h
0002 ST
11:48.07.1017
start time (1
st
photocell)
FT
11:48.09.2666
finish time (2
nd
photocell)
RT
0:02.165
run time
SP km/h
166.28
speed in km/h