Printer Linefeed
Menu 16
Default = 0
The printer can make blank lines after a printed paragraph (e. g. two blank lines so that the printout
moves across the tear-off edge). 1 to 9 blank lines can be set; if set to 0, in every line is printed.
Menu 16:
PRINTER LINEFEED = 0
enter number of blank lines
Save with: ENTER
confirm selection with <ENTER>
RS232 Baudrate
Menu 17
Default = 9600 BD
The baud rate for RS232 interface (d) can be set to 2400, 4800, 9600, 19200 Baud.
Menu 17:
RS-232 BAUDRATE
2400 Bd
F1
4800 Bd
F2
9600 Bd <
F3
Save with: ENTER
19200 Bd
F4
RS232 Run Time
Menu 18
Default = OFF
In difference time mode the stopped time of days is always output via RS232 interface (d). Additionally,
the run time can be output.
Menu 18:
RS-232 RUN TIME
ON
F1
output of run time
OFF<
F2
no output of run time
Save with: ENTER
confirm selection with <ENTER>
Display Board Baudrate
Menu 19
Default = 2400 Bd
The display board interface can be set to 2400, 4800, 9600 or 19200. For
ALGE
displays use 2400 Bd.
Starting with version V13.31 it is possible to turn the interface off (disable). To disable press the <arrow
key up> and then <F1>. With this version it sends the display board data also through RS485.
Starting with version V14.91 is the baud rate not automatically on 2400. The last used baud rate will
remain.
Menu 19:
D-BOARD BAUDRATE
2400 Bd
F1
4800 Bd
F2
9600 Bd <
F3
Save with: ENTER
19200 Bd
F4
Display Board channel 2
Menu 20
Default = RUNNING
The output can be set at channel 2 of the interface display board (e). Running time, standing times, or
best times can be output. The best time is always from the group if groups are used. For displaying the
best time the code switch of the display has to be set to position 2. A ranking is always output via the
display board interface (e) at channel 2. Switch between channel 1 and 2 by turning the plug by 180°.
Menu 20:
D-BOARD CHANNEL 2
RUNNING <
F1
output of running time
STANDING
F2
output of standing time
BEST TIME
F3
output of best time
Save with: ENTER
Beep
Menu 21
Default = ON
The beep sounds at every timing impulse. The length of the beep depends on the length of the delay
time. If the beep disturbs, it can be turned off. The beep is always activated after turning the device on.
Menu 21:
BEEP
ON
F1
beep activated
OFF <
F2
beep deactivated
WITH VALUED TIME
Save with: ENTER