OVERVOLTAGE ERROR
BATTERY
VOLTAGE
OVER LIMIT
Overvoltage error
If the battery open-circuit voltage
is greater than 14.0 V the charger
will not start and displays
"OVERVOLTAGE ERROR – BATTERY
VOLTAGE OVER LIMIT"
Remedy:
– observe correct operating mode
and correct voltage.
MAINS VOLTAGE ERROR
MAINS VOLTAGE
OUT OF RANGE
Mains voltage error
If the mains has voltages above or
below the permissible range the
charger will not start and displays
"MAINS VOLTAGE ERROR – MAINS
VOLTAGE OUT OF RANGE".
Remedy:
– check the mains conditions.
Error diagnosis
An electrical shock can be deadly.
Before opening the device
– disconnect it from the mains,
– disconnect the connection to the battery,
– attach an understandable warning sign against restarting
– Use a suitable measuring device to ensure that
electrically-charged components (e.g. condensers)
have discharged.
An insufficient protective grounded connection can result
in serious personal or material damages. The housing
screws represent a suitable protective grounded
connection for grounding the housing and may never be
replaced by other screws without a reliable protective
grounded connection.