"Diagnosis Support" operating mode
General
information
The "DIAGNOSIS SUPPORT" operating mode is exclusively used to
unburden the vehicle battery during a diagnosis or during a vehicle
software update. Over longer periods of time the discharged current
must be less than the maximum charge output current (40 A) otherwise
the battery becomes discharged. "STANDBY" operating mode is not
suitable for completely charging the battery.
Standby operation
1. Insert the charger's mains plug
0.0 V
0.0 A
70 Ah
CHARGE
SAFE
MODE SELECT
The "CHARGING" operating mode is
available once the charger has been
connected to the mains as standard.
2. Selecting the operating mode
CHARGE
REFRESH CHARGING
DIAGNOSIS SUPPORT
CONFIRM
EXIT
Select the operating mode using
the arrow keys and confirm your
selection with "CONFIRM".
3. Overview of selected settings
DIAGNOSIS SUPPORT
FOR ALL BATTERY TYPES
USE AS IN-VEHICLE
CHARGING WITH
13,8V AND 40A
IN VEHICLE
CONFIRM
EXIT
Diagnosis Support is suitable for all
battery types. The standby voltage
of 13.8 V is supplied at a maximum
standby current of 40 A. If the
maximum standby current is great-
er than 40 A, the standby voltage
decreases proportionally to the load.
Signalling methods for an overload
are described in the following items.
Danger of material damage if battery is defective.
Before starting DIAGNOSIS SUPPORT, ensure that the
battery to be buffered is fully functioning.