7. Connecting the battery - no sparks will be produced when the
battery is connected thanks to the voltage-free charging terminals
even if the charger has been connected to the mains.
– Connect the red charging clamps to the positive terminal (+) on
the battery.
– Connect the black charging clamps to the negative terminal (-) on
the battery.
12.4 V
TERMINAL VOLTAGE
OF BATTERY
0 Ah
CHARGED
69 Ah
REFRESH
WET
CONFIRM
Once the battery has been connected
to the charging clamps the charger
shows the terminal voltage at the
connected battery as a number
and as a battery symbol on the bar
display for 30 seconds. The charging
process starts automatically after
this.
You can skip the display of the
battery open-circuit voltage using
the "CONFIRM" key.
The battery must have an open-circuit voltage of at least 1.0 V for this
process. If the information window for the terminal voltage of battery
does not appear, the battery is an extremely exhausted battery of
below 1.0 V
0.0 V
0.0 A
69 Ah
REFRESH
WET
CONNECT BATTERY
OUT OF
VEHICLE
Alternatively, the charging start of
a deep discharge battery can also
be forced by pressing the left button
under the instruction „Connect
Battery“ for at least 5 seconds. This
leads to the safety query area.
8. Checking polarity when connecting exhausted batteries
CONFIRM
REFRESH MODE
CORRECT POLARITY?
CHECK THE CLAMPS!
If the battery has an open-circuit
voltage of less than 1.0 V, the polarity
will be queried for safety reasons.
The operator is then requested to
check the charging clamp polarity!
You then have to confirm the polarity
check using the "CONFIRM" key.