19
EN
General
information
The charger is suitable for 12V lead-acid batteries (wet-cell, AGM, EFB,
GEL) and 12V Li-Ion batteries.
Available
operating modes
The following operating modes are available:
–
CHARGING, charging batteries in or outside the vehicle
–
REFRESHER CHARGING, refresher-charging of exhausted batteries
outside the vehicle
–
DIAGNOSIS SUPPORT electrical system support during a diagnosis
or software updates to the vehicle,
–
POWER SUPPLY OPERATION, power supply mode for electrical
systems without fitted batteries or for power supply to disconnected
components.
–
SETTINGS, device settings
–
I-CHECK, power input check for VW Group testing
instructions for the purpose of guaranteeing provision for starter
batteries
Selecting
operating modes
Connect the power cable to the charger and plug into mains socket.
0.0 V
0.0 A
70 Ah
CHARGE
SAFE
MODE SELECT
CHARGE
REFRESH CHARGING
DIAGNOSIS SUPPORT
CONFIRM
EXIT
If mode selection is not shown,
charging operations start auto-
matically with the SAFE setting and
the battery capacity of 70 Ah as
soon as the battery terminals are
connected.
You can access the selection
menu using "MODE SELECT
"
and then scroll between the
operating modes using the arrow
keys. You can also simply achieve
this by pressing the arrow keys in the
menu. Select the operating mode
using the arrow keys and confirm
your selection with "CONFIRM".
Operating modes