6. Connecting the battery - no sparks will be produced when the
battery is connected thanks to the voltage-free charging terminals even
if the charger has been connected to the mains.
– Connect the red charging clamps to the positive terminal (+)
on the battery.
– Connect the black charging clamps to the negative terminal (-)
on the battery.
12.4 V
0 Ah
CHARGED
46 Ah
TERMINAL VOLTAGE
OF BATTERY
I-CHECK
WET
CONFIRM
Once the battery has been connected
to the charging clamps the charger
shows the terminal voltage at the
connected battery as a number and
as a battery symbol on the bar
display for 30 seconds. The charging
process starts automatically after
this.
You can skip display of the battery
open-circuit voltage using the
"CONFIRM" key.
The battery must have an open-circuit voltage of at least 1.0 V for this
process. If the battery voltage information window is not displayed the
battery is extremely deep-discharged at below 1.0 V.
7. Checking polarity when connecting deep-discharged batteries
I-CHECK
CORRECT POLARITY?
CHECK THE CLAMPS!
CONFIRM
The polarity will be queried the
safety reasons. The operator is then
requested to check the charging
clamp polarity! You then have to
confirm the polarity check using the
"CONFIRM" key.
0.0 V
0.0 A
I-CHECK
POLARITY
CHECKED
OUT OF
VEHICLE
START POWER
Then confirm the polarity check
by pressing the "START POWER"
key. The charger is now ready for
operation.
Material damage hazard if charging cable has incorrect
polarity. Always observe the charging cable polarity at the
battery.