13.8 V
36.4 A
POWER SUPPLY
NO BATTERY
USED
13.7 V
40.0 A
POWER SUPPLY
OVERLOAD – MAX. CURRENT
The current voltage and current
values are displayed and updated
every 0.5 seconds.
The charger supports the connected
consumers with maximum 40 A. If the
consumer is taking more than 40 A,
the voltage will decrease.
The charger display colour will
change from light blue to red every
second. On top of this the display
shows “OVERLOAD – MAX.
CURRENT”. The charger also gives
out an acoustic signal which can
be activated or deactivated in the
device settings.
6. Cancelling power supply operation
Press the STOP key during power
supply operation. Power supply
operation will be cancelled.
0.0 V
0.0 A
STOP
START
IN VEHICLE
EXIT
As soon as you press the STOP key
you will return to the initial area
of the "POWER SUPPLY OPERATION"
mode and you will have to confirm
all the safety queries again.
"POWER SUPPLY OPERATION" mode
can be continued by pressing the
left-hand "START" selection key.
Caution! There exists the danger that the supply voltage
continues to decrease due to overloading, and if this is
the case the application (e.g. flashing control units) will be
automatically stopped by the system if the voltage falls
below 12.0 V. This can result in hardware damage to the
control units.
Danger of spark formation on premature removal of the
charging cable. Press the STOP key to stop "POWER SUPPLY
OPERATION" before disconnecting the charging cable.
Damage hazard to connecting sockets and connecting
plugs. Do not unplug or disconnect the charging cables
during power supply operation.