34
0.0 V
0.0 A
DIAGNOSIS SUPPORT
IN VEHICLE
CONNECT VEHICLE
You should accept the additional
information about standby operation
by pressing the "CONFIRM" key.
The device is now ready for
operation.
4. Connecting the battery - no sparks will be produced when the
battery is connected thanks to the voltage-free charging terminals
even if the charger has been connected to the mains.
– Connect the red charging clamps to the positive terminal (+) on
the battery.
– Connect the black charging clamps to the negative terminal (-) on
the battery.
12.4 V
DIAGNOSIS SUPPORT
TERMINAL VOLTAGE
OF BATTERY
CONFIRM
Once the battery has been connected
to the charging clamps the charger
shows the terminal voltage at the
connected battery as a number and
as a battery symbol on the bar
display for 30 seconds. The charging
process starts automatically after
this.
You can skip display of the battery
open-circuit voltage using the
"CONFIRM" key.
The battery must have an open-circuit voltage of at least 1.0 V for this
process. If the information window for the terminal voltage of battery
does not appear, the battery is an extremely exhausted battery of
below 1.0 V. In this case we recommend using the "REFRESH" operating
mode for reactivating exhausted batteries. You can find more informa-
tion about this in the section on the "REFRESH" operating mode.
0.0 V
0.0 A
DIAGNOSIS SUPPORT
IN VEHICLE
CONNECT VEHICLE
Alternatively, the charging start of
a deep discharge battery can also
be forced by pressing the left button
under the instruction „Connect
Battery“ for at least 5 seconds. This
leads to the safety query area.