38
"Power supply" operating mode
General
information
In "POWER SUPPLY" operating mode the charging cables are connected
directly to the battery lines or the vehicle outside starting point. This
ensures that the on-board electronics is provided with power while the
battery is removed. Since only the vehicle's battery lines are connected
to the charger, the battery voltage detection function is not available.
Power supply
operation
1. Insert the charger's mains plug
0.0 V
0.0 A
70 Ah
CHARGE
SAFE
MODE SELECT
The "CHARGING" operating mode is
available once the charger has been
connected to the mains as standard.
2. Selecting the operating mode
POWER SUPPLY
SETTINGS
I-CHECK
CONFIRM
EXIT
Select the operating mode using
the arrow keys and confirm your
selection with "CONFIRM".
3. Overview of selected settings
POWER SUPPLY
USE AS POWER
SUPPLY WITHOUT A
BATTERY ONBOARD
WITH 13,8V AND 40A
IN VEHICLE
CONFIRM
EXIT
Power supply operation is designed
for applications without a battery.
The standby voltage of 13.8 V is
supplied at a maximum standby
current of 40 A.
The incorrect vehicle-specific voltage can cause serious
damage to the vehicle on-board electronics. It is
imperative that you check the correct voltage before
connecting the charger to the vehicle battery lines! Only
for 12 V applications.