45
EN
General
information
"I-CHECK" operating mode is used to determine the input power
capability of the discharged battery. The power input check is used
if a battery test which was previously carried out returned results
of "defective", "bad", "charge" or "tester will not start". The frame-
work conditions for the power input check are oriented using the
specifications provided in the VW Group test instructions.
The power input check runs as follows:
– automatic power input check within a few minutes.
– the power input check will be stopped and the results shown in
the display after a predefined testing time.
Power input check
1. Insert the charger's mains plug
0.0 V
0.0 A
70 Ah
CHARGE
SAFE
MODE SELECT
The "CHARGING" operating mode is
available once the charger has been
connected to the mains as standard.
2. Selecting the operating mode
POWER SUPPLY
SETTINGS
I-CHECK
CONFIRM
EXIT
Select the operating mode using
the arrow keys and confirm your
selection with "CONFIRM".
"I-Check" operating mode
Note!
The power input check can only be carried out
successfully on a discharged battery. A completely charged
battery will not pass the test.