Agilent X-Series Signal Generators SCPI Command Reference
207
Analog Modulation Commands
Frequency Modulation Subsystem–Option UNT ([:SOURce])
Frequency Modulation Subsystem–Option UNT ([:SOURce])
:FM[1]|2:EXTernal[1]|2:COUPling
Supported
All Models with Option UNT
[:SOURce]:FM[1]|2:EXTernal[1]|2:COUPling AC|DC
[:SOURce]:FM[1]|2:EXTernal[1]|2:COUPling?
This command sets the coupling for the frequency modulation source through the selected external
input connector.
Use this command with the
EXTernal[1]|2:DC
command to remove the effects of DC and optimize the
DCFM calibration.
AC
This choice only passes ac signal components.
DC
This choice passes both ac and dc signal components.
*RST
DC
Key Entry
Ext Coupling DC AC
Remarks
The command does not change the currently active source or switch the current
modulation on or off. The modulating signal may be the sum of several signals,
either internal or external sources.
:FM[1]|2:EXTernal[1]|2:IMPedance
Supported
All Models with Option UNT
[:SOURce]:FM:EXTernal[1]|2:IMPedance 50|600|1000000
[:SOURce]:FM:EXTernal[1]|2:IMPedance?
This command sets the input impedance for the externally- applied FM input signal.
50
This choice selects 50 Ohm input impedance.
600
This choice selects 600 Ohm input impedance.
1000000
This choice selects 1 MOhm input impedance.
*RST
50 Ohm
:FM[1]|2:INTernal:DUAL:FUNCtion2:AMPLitude:PERCent
Supported
All Models with Options UNT and 303
[:SOURce]:FM[1]|2:INTernal:DUAL:FUNCtion2:AMPLitude:PERCent <value><unit>
[:SOURce]:FM[1]|2:INTernal:DUAL:FUNCtion2:AMPLitude:PERCent?
This command sets the amplitude of tone 2 of the internal dual function generator source as a
percent of the peak analog modulation amplitude. Tone 1 of the internal dual function generator
source will make up the remaining amplitude.
Key Entry
Ext Impedance
50 Ohm
600 Ohm
1 MOhm
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...