Agilent X-Series Signal Generators SCPI Command Reference
223
Analog Modulation Commands
Low Frequency Output Subsystem ([:SOURce]:LFOutput)
:SWEep:FUNCtion:FREQuency:STOP
Supported
All Models with Options UNT and 303
[:SOURce]:LFOutput:SWEep:FUNCtion:FREQuency:STOP <val><units>
[:SOURce]:LFOutput:SWEep:FUNCtion:FREQuency:STOP?
This command sets the stop frequency for the swept function generator.
*RST
400.0 Hz
Range
100 mHz to 6.250 MHz
Key Entry
LF Out Stop Freq
:SWEep:FUNCtion:SHAPe
Supported
All Models with Options UNT and 303
[:SOURce]:LFOutput:SWEep:FUNCtion:SHAPe SINE|TRIangle|SQUare|RAMP
[:SOURce]:LFOutput:SWEep:FUNCtion:SHAPe?
This command sets the waveform type for the swept function generator.
*RST
SINE
:SWEep:FUNCtion:SHAPe:RAMP
Supported
All Models with Options UNT and 303
[:SOURce]:LFOutput:SWEep:FUNCtion:SHAPe:RAMP POSitive|NEGative
[:SOURce]:LFOutput:SWEep:FUNCtion:SHAPe:RAMP?
This command sets the ramp direction for the swept function generator when
:SWEep:FUNCtion:SHAPe
is set to RAMP.
*RST
POS
:SWEep:RATE[1]|2
Supported
All Models with Options UNT and 303
[:SOURce]:LFOutput:SWEep:RATE[1]|2 <val><units>
[:SOURce]:LFOutput:SWEep:RATE[1]|2?
This command sets the sweep rate for the swept–sine waveform.
The sweep rate function is only available for internal source 1.
*RST
+4.00002
Range
0.5 Hz to 100 kHz
Key Entry
LF Out Sweep Rate
Key Entry
LF Out Sweep Waveform
Key Entry
Pos Ramp
Neg Ramp
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...