Agilent X-Series Signal Generators SCPI Command Reference
221
Analog Modulation Commands
Low Frequency Output Subsystem ([:SOURce]:LFOutput)
This command sets the noise type when
:SOURce
is set to NOISe[1] or NOISe2.
*RST
POS
:OFFset
Supported
All Models with Option UNT
[:SOURce]:LFOutput:OFFset <value><unit>
[:SOURce]:LFOutput:OFFset?
This command sets the DC offset (in volts) of the signal at the LF Output connector.
*RST
0.000 V
:SOURce
Supported
All Models with Options UNT and 303
[:SOURce]:LFOutput:SOURce MONitor|FUNCtion[1]|FUNCtion2|SWEep|DUAL|NOISe[1]|NOISe2|DC
[:SOURce]:LFOutput:SOURce?
This command selects the source for the LF output.
MONitor
Selects monitoring on the LF output BNC. Select the monitoring source using the
:SOURce:MONitor
command.
FUNCtion[1]
Selects function generator 1 as the modulation source.
FUNCtion[2]
Selects function generator 2 as the modulation source.
SWEep
Selects the swept function generator as the LF output BNC source. If AM or FM or
PM is modulating the swept function generator then the LF output BNC will have
the unmodulated signal if you choose to monitor the swept function generator.
DUAL
Selects the dual function generator as the modulation source.
NOISe[1]
Selects noise generator 1 as the modulation source.
NOISe2
Selects noise generator 2 as the modulation source.
DC
Selects a DC voltage level as the LF output BNC source.
*RST
MONitor
Remarks
Only MON, FUNC1 and DC are available without Option 303.
:SOURce:MONitor
Supported
All models with Option UNT
[:SOURce]:LFOutput:SOURce:MONitor FUNCtion[1]|FUNCtion2|SWEep|DUAL
Key Entry
Uniform
Gaussian
Range
- 10.000 to 10.000 V
Key Entry
LF Out DC Offset Into 50 Ohms
LF Out DC Offset Into 1 MOhms
Key Entry
Int Monitor
Func Gen 1
Dual Func Gen
Noise Gen 1
DC
Func Gen 2
Swept Func Gen
Noise Gen 2
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...