
304
Agilent X-Series Signal Generators SCPI Command Reference
Arb Commands
Dual ARB Subsystem–N5172B/82B ([:SOURce]:RADio:ARB)
With the multiple baseband generator synchronization feature active, this selection
is unavailable (see
page 284
for more information).
TRIGger
The waveform waits for a trigger before play begins. When the waveform receives
the trigger, it plays continuously until you turn the format off, select another
trigger, or choose another waveform file.
RESet
The waveform waits for a trigger before play begins. When the waveform receives
the trigger, it plays continuously. Subsequent triggers reset the waveform to the
beginning. For a waveform sequence, this means to the beginning of the first
segment in the sequence.
*RST
FREE
:TRIGger:TYPE:GATE
Supported
N5172B/82B
[:SOURce]:RADio:ARB:TRIGger:TYPE:GATE LOW|HIGH
[:SOURce]:RADio:ARB:TRIGger:TYPE:GATE?
This command selects the active state (gate polarity) of the gate while using the gating trigger mode.
The LOW and HIGH selections correspond to the low and high states of an external trigger signal.
For example, when you select HIGH, the active state occurs during the high of the trigger signal.
When the inactive state occurs, the X- Series signal generator stops the waveform playback at the last
played sample point, then restarts the playback at the next sample point when the active state
occurs. For more information on triggering and to select gating as the trigger mode, see
“:TRIGger:TYPE” on page 302
.
The following list describes the X- Series signal generator’s gating behavior for the polarity selections:
LOW
The waveform playback stops when the trigger signal goes high and restarts when
the trigger signal goes low.
HIGH
The waveform playback stops when the trigger signal goes low and restarts when
the trigger signal goes high.
*RST
HIGH
:TRIGger:TYPE:SADVance[:TYPE]
Supported
N5172B/82B
[:SOURce]:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE] SINGle|CONTinuous
[:SOURce]:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE]?
This commands selects the waveform’s response to a trigger signal while using the segment advance
(SADVance) trigger mode.
When the X- Series signal generator receives multiple trigger occurrences when only one is required,
the signal generator uses the first trigger and ignores the rest. For more information on triggering
and to select segment advance as the trigger mode, see
“:TRIGger:TYPE” on page 302
.
The following list describes the waveform’s response to each of the command choices:
Key Entry
Free Run
Trigger & Run
Reset & Run
Key Entry
Active Low
Active High
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...