Status Subsystem (:STATus)
:QUEStionable:MODulation:CONDition?
Supported
All Models
:STATus:QUEStionable:MODulation:CONDition?
This command returns the decimal sum of the bits in the Data Questionable Modulation Condition
Register. For example, if the modulation is uncalibrated (bit 4), a value of 16 is returned.
Range
0 to 32767
Remarks
The data in this register is continuously updated and reflects current conditions.
Refer to the
Programming Guide
for more information.
:QUEStionable:MODulation:ENABle
Supported
All Models
:STATus:QUEStionable:MODulation:ENABle <val>
:STATus:QUEStionable:MODulation:ENABle?
This command determines which bits in the Data Questionable Modulation Event Register will set the
modulation summary bit (bit 7) in the Data Questionable Condition Register.
The variable <val> is the sum of the decimal values of the bits that you want to enable.
Range
0 to 32767
Remarks
Refer to the
Programming Guide
for more information.
:QUEStionable:MODulation:NTRansition
Supported
All Models
:STATus:QUEStionable:MODulation:NTRansition <val>
:STATus:QUEStionable:MODulation:NTRansition?
This command determines which bits in the Data Questionable Modulation Condition Register will set
the corresponding bit in the Data Questionable Modulation Event Register when that bit has a
negative transition (1 to 0).
The variable <val> is the sum of the decimal values of the bits that you want to enable.
Range
0 to 32767
Remarks
Refer to the
Programming Guide
for more information.
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...