158
Agilent X-Series Signal Generators SCPI Command Reference
System Commands
Status Subsystem (:STATus)
:QUEStionable:FREQuency:NTRansition
Supported
All Models
:STATus:QUEStionable:FREQuency:NTRansition <value>
:STATus:QUEStionable:FREQuency:NTRansition?
This command determines which bits in the Data Questionable Frequency Condition Register will set
the corresponding bit in the Data Questionable Frequency Event Register when that bit has a
negative transition (1 to 0).
The variable <value> is the sum of the decimal values of the bits that you want to enable.
Range
0 to 32767
Remarks
Refer to the
Programming Guide
for more information.
:QUEStionable:FREQuency:PTRansition
Supported
All Models
:STATus:QUEStionable:FREQuency:PTRansition <value>
:STATus:QUEStionable:FREQuency:PTRansition?
This command determines which bits in the Data Questionable Frequency Condition Register will set
the corresponding bit in the Data Questionable Frequency Event Register when that bit has a positive
transition (0 to 1).
The variable <value> is the sum of the decimal values of the bits that you want to enable.
Range
0 to 32767
Remarks
Refer to the
Programming Guide
for more information.
:QUEStionable:FREQuency[:EVENt]?
Supported
All Models
CAUTION
This is a destructive read. The data in the register is latched until it is queried. Once
queried, the data is cleared.
:STATus:QUEStionable:FREQuency[:EVENt]?
This query returns the decimal sum of the bits in the Data Questionable Frequency Event Register.
Range
0 to 32767
Remarks
The equivalent PTR or NTR filters must be set before the condition register can
set the corresponding bit in the event register.
Refer to the
Programming Guide
for more information.
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...