Agilent X-Series Signal Generators SCPI Command Reference
89
Basic Function Commands
Vector Modulation Subsystem—N5172B/82B ([:SOURce]:IQ)
SNR
Selects Signal to Noise Ratio (SNR) to control the ratio of signal power to noise
power in the noise integration bandwidth.
EBNO
Selects energy per chip over noise power density at the receiver (Ec/No) to control
the ratio of signal power to noise power in the noise integration bandwidth.
*RST
SNR
Key Entry
Signal to Noise Ratio Format
:OUTPut:IMPairments:AWGN[:STATe]
Supported
N5172B with Option 653 or 655, N5182B with Option 656 or 657
[:SOURce]:IQ:OUTPut:IMPairments:AWGN[:STATe] ON|OFF|1|0
[:SOURce]:IQ:OUTPut:IMPairments:AWGN[:STATe]?
This command enables or disables the additive white Gaussian noise.
*RST
0
Key Entry
Real-Time AWGN On Off
:OUTPut:IMPairments:PHASe:NOISe:F1
Supported
N5172B with Option 653 or 655, N5182B with Option 656 or 657
[:SOURce]:IQ:OUTPut:IMPairments:PHASe:NOISe:F1 <value>
[:SOURce]:IQ:OUTPut:IMPairments:PHASe:NOISe:F1?
This command sets the desired start frequency offset of the flat phase noise. The actual value of f1
varies logarithmically depending on the value of the stop frequency (f2). As f2 increases in value, the
adjustment becomes coarser. The effect of this value can only be determined by examining the
graphic on the front panel or the actual output.
NOTE: This phase noise is added to the base phase noise of the instrument.
f1 must always be less than or equal to f2. Setting f1 higher than f2 will cause f2 to be set to the
value of f1.
*RST
1 kHz
Range
0 Hz to 77.50052449 MHz
Key Entry
Desired Start Freq(F1)
:OUTPut:IMPairments:PHASe:NOISe:F2
Supported
N5172B with Option 653 or 655, N5182B with Option 656 or 657
[:SOURce]:IQ:OUTPut:IMPairments:PHASe:NOISe:F2 <value>
[:SOURce]:IQ:OUTPut:IMPairments:PHASe:NOISe:F2?
This command sets the desired stop frequency offset of the flat phase noise. The actual value of f2
varies logarithmically. As f2 increases in value, the adjustment becomes coarser. The effect of this
value can only be determined by examining the graphic on the front panel or the actual output.
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...