72
Agilent X-Series Signal Generators SCPI Command Reference
Basic Function Commands
Power Subsystem ([:SOURce]:POWer)
Key Entry
Power Meter Servo mode overshoot protection increment threshold
:ALC[:STATe]
Supported
All Models
[:SOURce]:POWer:ALC[:STATe] ON|OFF|1|0
[:SOURce]:POWer:ALC[:STATe]?
This command enables or disables the automatic leveling control (ALC) circuit. The query returns the
current state of the ALC.
*RST
1
Key Entry
ALC Off On
Remarks
The purpose of the ALC circuit is to hold output power at a desired level by
adjusting the signal generator’s power circuits to compensate for power drift.
Power drift occurs over time and changes in temperature. Refer to the
User’s
Guide
for more information on the ALC.
:ALC:TRANsition:REFerence
Supported
N5172B/82B
[:SOURce]:POWer:ALC:TRANsition:REFerence RMS|MODulated|NBModulated
[:SOURce]:POWer:ALC:TRANsition:REFerence?
This command determines the ALC settling mode during frequency transitions when the IQ
modulator is on.
RMS
This choice is the default behavior. The IQ is set to an idle state and a CW only
signal plays during frequency transitions.
Mod
This choice leaves the IQ on during frequency transition and also leaves the ALC
in the default wide bandwidth mode for fast switching.
Although this choice results in switching times that are equivalent to RMS mode,
there is the possibility of leveling at the wrong power level.
NBMod
This choice leaves the IQ on during frequency transitions but sets the ALC
bandwidth to a narrow bandwidth. Doing this increases the switching time but
allows for a more accurate amplitude level.
*RST
RMS
Key Entry
ALC Transition Reference RMS Mod NBMod
Remarks
RMS is the default behavior and in most cases is the best choice for this setting.
Refer to the
User’s Guide
for more information on the ALC.
:ALCHold:EXTernal:SOURce
Supported
All Models
:ALCHold:EXTernal:SOURce TRIGger[1]|TRIGger2|PULSe
:ALCHold:EXTernal:SOURce?
Содержание 72B
Страница 28: ...Contents Agilent X Series Signal Generators SCPI Command Reference xxviii ...
Страница 48: ...18 Agilent X Series Signal Generators SCPI Command Reference SCPI Basics SCPI Basics ...
Страница 224: ...194 Agilent X Series Signal Generators SCPI Command Reference System Commands Unit Subsystem UNIT ...
Страница 458: ...428 Agilent X Series Signal Generators SCPI Command Reference Index ...