VIII
Working Environment
General requirements
Environment
This product is intended for indoor use and should be operated in a clean, dry environment.
It can be stored in an environment with a waterproof/dustproof rating better than IP51.
Temperature
Operating: 32˚ to 105˚F (0˚ - 40˚ C)
Non-operating: -5˚ to 140˚F (-20˚ - 60˚ C)
Note:
Direct sunlight, radiators, and other heat sources should be taken into account when assessing the ambient
temperature.
Humidity
Operating: 85% RH, 105˚F (40˚ C) , 24 hours
Non-operating: 85% RH, 150˚F (65˚ C), 24 hours
Altitude
Operating: less than 1.2 mi/2 km
Non-operating: less than 3 mi/5 km
Installation (overvoltage) Category
This product is powered by mains conforming to installation (overvoltage) category II.
WARNING
Overvoltage while operating on line power (from lightning, for instance) creates the risk of electric
shock for the user.
Installation (overvoltage) Category Definitions
Installation (overvoltage) category I refers to signal level. This applies to circuits with measures in place to limit
the transient voltage to the corresponding low level.
Installation (overvoltage) category II refers to the local power distribution level. This applies to equipment
running on “wall power”.
Degree of Pollution
The oscilloscope may be operated in environments up to Pollution Degree II.
Note:
Pollution Degree II refers to a dry working environment and non-conductive pollution. Occasional
temporary conductivity caused by condensation is expected.
IP Rating
IP51 (as defined in IEC 60529)
Содержание OSC-9200
Страница 1: ...AEGIS Shaft Voltage Tester Handheld Digital Oscilloscope AEGIS OSC 9200...
Страница 18: ...3 Appearance and Dimensions mm Figure 1 Front View Figure 2 Side view...
Страница 44: ...29 Horizontal Control Contents u Horizontal Scale u Horizontal Delay u Roll Mode u Zoom Mode...
Страница 56: ...41 Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 60: ...45 Figure 21 With Random Noise Normal Mode Figure 22 With Random Noise Average Mode...
Страница 101: ...86 l R W the type of a frame write or read l Data the value of the data Figure 42 I2C Decode List Display...
Страница 105: ...90...
Страница 116: ...101 l CRC the value of CRC Cyclic Redundancy Check field l ACK Acknowledgment bit Figure 57 CAN Decode List Displa...
Страница 135: ...120 Figure 75 Integral with Offset...
Страница 139: ...124 Figure 77 Measure Pulse Width...
Страница 146: ...131 Figure 83 Added the Measurement Note if the parameter does not match the measure condition it will display as...
Страница 190: ...175 DC Current Measurement AC Current Measurement...
Страница 204: ...info est aegis com www est aegis com...