![Aegis OSC-9200 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/aegis/osc-9200/osc-9200_user-manual_2860410048.webp)
33
Zoom Mode
Zoom is a horizontally expanded version of the normal display. You can use Zoom to locate and
(horizontally) expand part of the normal window for a more detailed (higher-resolution) view.
Press
Shift
and
Clear Sweep
on the front panel to turn on the zoom function, and press them again
to turn it off. When Zoom is on, the display window splits in half. The top half shows the main window
and the bottom half displays a faster (less time/div) zoom window.
Figure 14 Split Screen Zoom
The zoomed-in area of the normal window is outlined with a border, and the rest of the normal window
is shaded. The selected area is zoomed in on at the bottom of the screen.
To change the time base for the Zoom window, press
Horizontal Scale
. The
Horizontal Scale
button
controls the size of the border area. The
Horizontal Position
button sets the left-to-right position of
the zoom window. The delay value, which is the time displayed relative to the trigger point, is
momentarily displayed in the upper-right corner when you press
Horizontal Position
. Negative delay
values indicate you're looking at a portion of the waveform before the trigger event, and positive values
indicate you're looking at the waveform after the trigger event.
To change the time base of the normal window, turn off Zoom; then press
Horizontal Scale
.
Содержание OSC-9200
Страница 1: ...AEGIS Shaft Voltage Tester Handheld Digital Oscilloscope AEGIS OSC 9200...
Страница 18: ...3 Appearance and Dimensions mm Figure 1 Front View Figure 2 Side view...
Страница 44: ...29 Horizontal Control Contents u Horizontal Scale u Horizontal Delay u Roll Mode u Zoom Mode...
Страница 56: ...41 Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 60: ...45 Figure 21 With Random Noise Normal Mode Figure 22 With Random Noise Average Mode...
Страница 101: ...86 l R W the type of a frame write or read l Data the value of the data Figure 42 I2C Decode List Display...
Страница 105: ...90...
Страница 116: ...101 l CRC the value of CRC Cyclic Redundancy Check field l ACK Acknowledgment bit Figure 57 CAN Decode List Displa...
Страница 135: ...120 Figure 75 Integral with Offset...
Страница 139: ...124 Figure 77 Measure Pulse Width...
Страница 146: ...131 Figure 83 Added the Measurement Note if the parameter does not match the measure condition it will display as...
Страница 190: ...175 DC Current Measurement AC Current Measurement...
Страница 204: ...info est aegis com www est aegis com...